6

Avoiding Damage to the Instrument   

1.

 

Do not attempt to operate the device if damage is suspected. 

2.

 

Protect  this  unit  from  physical  damage,  corrosive  agents  and  extreme 
temperatures (direct sunlight, etc.). 

3.

 

For proper ventilation and safety concerns, keep at least 10 cm of space behind 
the instrument, and at least 5 cm of space on each side. 

4.

 

Use high level of precaution against the damages on the unit. 

5.

 

Do not operate the unit out of environmental conditions addressed above. 

6.

 

Do not operate the power supplies in high humidity environments (> 95%), or 
where condensation may occur. 

7.

 

To avoid condensation after operating the power supply in a cold room, wrap 
the unit in a plastic bag and allow at least 2 hours for the unit to equilibrate to 
room temperature before removing the bag and operating the unit. 

8.

 

Prior  to  applying  any  cleaning  or  decontamination  methods  other  than 
manufacturer’s recommendation, users should check with the manufacturer’s 
instruction to see if the proposed method will damage the equipment. 

 

Equipment Operation   

Follow the guidelines below to ensure safe operation of the unit: 
1. NEVER access dangerous chemicals or other materials to prevent possible hazard of 

explosion and damage. 

2. Do not operate the unit without lids or covers to prevent possible hazards. 

3.  A  temporary  conductivity  caused  by  condensation  might  occur  even  though  this 
series is rated Pollution Degree 2 in accordance with IEC 664. 
 

Symbol   

Symbols used on the power supply are explained below.

 

 

 

Indicates an area where a potential shock hazard may exist. 
Consult the manual to avoid possible personal injury or instrument damage. 

 

 

 

Indicates disposal instruction. 
DO NOT throw this unit into a municipal trash bin when this unit has reached 

the end of its lifetime. To ensure utmost protection of the global environment 

and minimize pollution, please recycle this unit. 

 

 

 

Caution/ Warning: Indicates a hazardous situation which, if not avoided, 
could result in death or serious injury.   

 

Содержание PowerPro300

Страница 1: ...Version 1 Revised on 2017 7 19 PowerPro Power Supplies Instruction manual Catalog No PowerPro300 PowerPro3AMP PowerPro500 www cleaverscientific com...

Страница 2: ...TION 10 SECTION 3 INSTALLATION INSTRUCTIONS 11 SECTION 4 OPERATION INSTRUCTIONS 11 4 1 CONTROL INTERFACE 11 4 2 START THE OPERATION 12 4 3 CONSTANT MODE 13 4 4 PROGRAM MODE 16 4 5 TYPICAL RUNNING COND...

Страница 3: ...1x Power Cord 1x Instruction Manual Packing list checked by ________________________ Date ____________ Cleaver Scientific is liable for all missing or damaged parts accessories within 7 days after cu...

Страница 4: ...ts carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to follow these directions could result in personal and or laborat...

Страница 5: ...ollution degree 2 7 Mains supply voltage fluctuations up to 10 of the normal voltage Avoiding Electrical Shock Follow the guidelines below to ensure safe operation of the unit The PowerPro Power Suppl...

Страница 6: ...turer s recommendation users should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe ope...

Страница 7: ...re 1 Risk assessment table Potential Risk Frequency Frequent Likely Possible Rare Unlikely Bruise Slash Electrical shock Power cord plug wrong 2 Preventative measures of risk Potential Risk Preventive...

Страница 8: ...majority of electrophoresis applications on the market Sufficient and accurate output voltages five terminal pairs and its compacted size can deliver accurate and reliable experimental results from o...

Страница 9: ...multi electrophoresis units simultaneously Cleaver Scientific PowerPro Series Power Supply provides Constant Voltage or Constant Current or Constant Power to instruments used in electrophoresis 5 ter...

Страница 10: ...age 30 programmed files Program Multi Step Up to 6 steps Editable Program Function 1 Have typical running conditions program 2 Manual editable program Display 2 4 TFT Control Microprocessor controller...

Страница 11: ...ady for operation Section 4 Operation Instructions 4 1 Control interface Button Functions No Icon Function 1 Press to activate or stop the unit 2 Press to temporarily interrupt power to an operation i...

Страница 12: ...ker near the AC cord on the back of the unit and plug the other end into the main power socket 3 Connect the DC output jacks from the electrophoresis unit insert the red lead into the red output jack...

Страница 13: ...current limit and power limit continuously during the entire operation of electrophoresis Note When target constant mode is set system automatically adjusts the other two parameters to maximum to all...

Страница 14: ...W or time min Press Key to set the specified parameter Use or to set the appropriate value and then press Key and move to the next parameter until all the parameters are set in the same operation met...

Страница 15: ...setting screen Adjust the values and then press Key to resume your operation If you want to change values of parameters and start a new operation run during current running press Key instead of After...

Страница 16: ...s convenience After starting the operation see the above 4 2 instruction set the Program Mode as follow Use Key and Key to select Program Mode and then press either or to enter the next page Press or...

Страница 17: ...Press Key to terminate a timed run and turn the AC power OFF by the switch on the back Note It would take a little time about 5 seconds for the unit to power off Press to switch pages between real ti...

Страница 18: ...rs during current running but do not want to terminate the time run you may pause electrophoresis by pressing the Key Press Key to enter the setting screen Adjust the values and then press Key to resu...

Страница 19: ...are 4 categories that can be selected Choose the model according to your experiment need After selecting model the preset value will display User could adjust the value or simply just press to start o...

Страница 20: ...fic service department Operation stops and the screen displays Communication wires on circuit board have loosen or broken It is recommended to send the machine back to local distributor or our Service...

Страница 21: ...again restart application If you cannot restart the instrument turn off the power disconnect the power cord from the outlet and contact Technical Service Operation stops with alarm Display shows Circu...

Страница 22: ...en cut and now recover User does not need to take extra action The warning sign and beep sound would only last for 5 second after that the machine will continue running the unfinished project The sign...

Страница 23: ...fuses are burned or there is a break in the fuses element replace the fuses with identical type of fuses 4 Place the fuses holder back into the compartment 5 Snap the cover closed For additional fuse...

Страница 24: ...iability under the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be prese...

Отзывы: