Warning 

 

Cleaver Scientific PowerPro Power Supply has been tested and found to comply with 
the limits for the CE regulation. Also, it is RoHS compliant to deliver confident product 

which  meets  the  environmental  directive.  These  limits  are  designed  to  provide 

reasonable  protection  against  harmful  interference  when  the  instrument  series  is 
operated  in  a  commercial  environment.  This  instrument  series  used  together  with 
power supply unit generates, uses, and can radiate radio frequency energy, and if not 
installed  and  used  in  accordance  with  the  instruction  manual,  may  cause  harmful 
interference  to  radio  communications.  Operation  of  this  instrument  series  in  a 
residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at their expense. Changes or modifications not 
expressly  approved  by  the  party  responsible  for  compliance  could  void  the  user’s 

authority to operate the equipment. It is strongly recommended for the user to read 
the following points carefully before operating this equipment. 

 

1.

 

Read and follow the manual instructions carefully. 

2.

 

Do  not  alter  the  equipment.  Failure  to  follow  these  directions  could  result  in 

personal and/or laboratory hazards, as well as invalidate equipment warranty. 

3.

 

Use  a  properly  grounded  electrical  outlet  with  correct  voltage  and  current 

handling capacity. 

4.

 

Disconnect from power supply before maintenance and servicing. Refer servicing 

to qualified personnel. 

5.

 

Never  use  this  instrument  series  without  having  the  safety  cover  correctly  in 
position. 

6.

 

Do not use the unit if there is any sign of damage to the external tank or cover. 

Replace damaged parts. 

7.

 

Do  not  use  in  the  presence  of  flammable  or  combustible  material;  fire  or 

explosion  may  result.  This  device  contains  components  which  may  ignite  such 

materials. 

8.

 

Refer maintenance and servicing to qualified personnel. 

9.

 

Ensure that the system is connected to electrical service according to local and 

national electrical codes. Failure to make a proper connection may create fire or 

shock hazard. 

10.

 

Use  appropriate  materials  and  operate  correctly  to  avoid  possible  hazards  of 
explosion,  implosion  or  release  of  toxic  or  flammable  gases  arising  from 

overheated materials. 

Содержание PowerPro300

Страница 1: ...Version 1 Revised on 2017 7 19 PowerPro Power Supplies Instruction manual Catalog No PowerPro300 PowerPro3AMP PowerPro500 www cleaverscientific com...

Страница 2: ...TION 10 SECTION 3 INSTALLATION INSTRUCTIONS 11 SECTION 4 OPERATION INSTRUCTIONS 11 4 1 CONTROL INTERFACE 11 4 2 START THE OPERATION 12 4 3 CONSTANT MODE 13 4 4 PROGRAM MODE 16 4 5 TYPICAL RUNNING COND...

Страница 3: ...1x Power Cord 1x Instruction Manual Packing list checked by ________________________ Date ____________ Cleaver Scientific is liable for all missing or damaged parts accessories within 7 days after cu...

Страница 4: ...ts carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to follow these directions could result in personal and or laborat...

Страница 5: ...ollution degree 2 7 Mains supply voltage fluctuations up to 10 of the normal voltage Avoiding Electrical Shock Follow the guidelines below to ensure safe operation of the unit The PowerPro Power Suppl...

Страница 6: ...turer s recommendation users should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe ope...

Страница 7: ...re 1 Risk assessment table Potential Risk Frequency Frequent Likely Possible Rare Unlikely Bruise Slash Electrical shock Power cord plug wrong 2 Preventative measures of risk Potential Risk Preventive...

Страница 8: ...majority of electrophoresis applications on the market Sufficient and accurate output voltages five terminal pairs and its compacted size can deliver accurate and reliable experimental results from o...

Страница 9: ...multi electrophoresis units simultaneously Cleaver Scientific PowerPro Series Power Supply provides Constant Voltage or Constant Current or Constant Power to instruments used in electrophoresis 5 ter...

Страница 10: ...age 30 programmed files Program Multi Step Up to 6 steps Editable Program Function 1 Have typical running conditions program 2 Manual editable program Display 2 4 TFT Control Microprocessor controller...

Страница 11: ...ady for operation Section 4 Operation Instructions 4 1 Control interface Button Functions No Icon Function 1 Press to activate or stop the unit 2 Press to temporarily interrupt power to an operation i...

Страница 12: ...ker near the AC cord on the back of the unit and plug the other end into the main power socket 3 Connect the DC output jacks from the electrophoresis unit insert the red lead into the red output jack...

Страница 13: ...current limit and power limit continuously during the entire operation of electrophoresis Note When target constant mode is set system automatically adjusts the other two parameters to maximum to all...

Страница 14: ...W or time min Press Key to set the specified parameter Use or to set the appropriate value and then press Key and move to the next parameter until all the parameters are set in the same operation met...

Страница 15: ...setting screen Adjust the values and then press Key to resume your operation If you want to change values of parameters and start a new operation run during current running press Key instead of After...

Страница 16: ...s convenience After starting the operation see the above 4 2 instruction set the Program Mode as follow Use Key and Key to select Program Mode and then press either or to enter the next page Press or...

Страница 17: ...Press Key to terminate a timed run and turn the AC power OFF by the switch on the back Note It would take a little time about 5 seconds for the unit to power off Press to switch pages between real ti...

Страница 18: ...rs during current running but do not want to terminate the time run you may pause electrophoresis by pressing the Key Press Key to enter the setting screen Adjust the values and then press Key to resu...

Страница 19: ...are 4 categories that can be selected Choose the model according to your experiment need After selecting model the preset value will display User could adjust the value or simply just press to start o...

Страница 20: ...fic service department Operation stops and the screen displays Communication wires on circuit board have loosen or broken It is recommended to send the machine back to local distributor or our Service...

Страница 21: ...again restart application If you cannot restart the instrument turn off the power disconnect the power cord from the outlet and contact Technical Service Operation stops with alarm Display shows Circu...

Страница 22: ...en cut and now recover User does not need to take extra action The warning sign and beep sound would only last for 5 second after that the machine will continue running the unfinished project The sign...

Страница 23: ...fuses are burned or there is a break in the fuses element replace the fuses with identical type of fuses 4 Place the fuses holder back into the compartment 5 Snap the cover closed For additional fuse...

Страница 24: ...iability under the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be prese...

Отзывы: