22
• Dielectric tubes:
Dielectric tubes are located in the reaction chambers of the ozone generator. These tubes should be inspected
periodically and cleaned if necessary. Once each year, remove one reaction chamber and inspect the dielectric
tube for debris. If the tube is clean and free of any debris, oil or dirt, it may be replaced and no further maintenance
is required. If the tube is dirty or cracked, all dielectric tubes must be inspected and cleaned. Cracked dielectrics
should be replaced. Please consult your ClearWater Tech distributor, as the improper installation of the dielectric
may cause safety problems!
Since the air that is introduced into the reaction chambers is high quality, the dielectric tubes should remain clean
for at least one year before inspection is required.
Removal of the Dielectric Tubes
1.
Disconnect all the power to the system, including panel breakers, service disconnect box and main
circulation pump interlock.
2.
Unplug the electrical terminal on the back of the drive module, disconnect the polypropylene barbed air
fitting and the Kynar
®
ozone fitting.
3.
Remove the ozone reaction chamber(s) from the back plate.
4.
Disconnect the high voltage wire from the coil. Remove the stainless steel nut and Kynar
®
center rod from
the center of the reaction chamber.
5.
The Teflon
®
end caps can now be gently removed by slowly pulling straight out. The glass dielectric will
remain attached to one of the end caps.
6.
If the dielectric tube is dirty, clean the glass with Isopropyl alcohol. Do not use a solvent that will leave an
oily residue.
7.
Clean the inside of the stainless steel reaction chamber with a wire brush as necessary, then wipe with
Isopropyl alcohol.
8.
Be sure all solvents have evaporated prior to reassembly.
Re-Installation of the Dielectric Tubes
1.
Inspect the O-rings and replace as necessary.
2.
Tighten the end caps so that they are approximately 1/8” from the aluminum extrusion.
3.
Replace the reaction chambers and connect the air and ozone lines.
4.
Connect the high voltage wire to the coil.
5.
Readjust the system as necessary (see operating instructions).
• Replace the particulate air filter located inside the ozone generator cabinet annually.
Air Preparation
Clean the filter located on the side of the oxygen generator monthly. Contact your ClearWater Tech distributor for annual
service of the air compressor.
If the unit must be returned to ClearWater Tech for repair or evaluation, follow the steps outlined below:
1.
Make sure the main power to the unit is disconnected.
2.
Disconnect the ozone delivery line.
3.
Disconnect the power lines inside the electrical interlock box.
4.
Wire nut all disconnected wires.
5.
Prepare for shipment and ship according to the instructions provided by your ClearWater Tech distributor.
Annual maintenance agreements for your ClearWater Tech system are available from your ClearWater Tech
distributor.
Содержание CD15/O2
Страница 8: ...7 M 15 02 UNIT DIAGRAM ...
Страница 9: ...8 CD15 02 UNIT DIAGRAM ...
Страница 10: ...9 P 20 02 UNIT DIAGRAM ...
Страница 11: ...10 CD 20 02 UNIT DIAGRAM ...
Страница 13: ...12 M 15 02 CD 15 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 14: ...13 P 20 2 CD 20 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 16: ...15 M 15 02 CD 15 02 INTERLOCK WIRING CONNECTIONS ...
Страница 17: ...16 P 20 2 CD 20 02 INTERLOCK WIRING CONNECTIONS ...
Страница 28: ...27 ENLARGED VIEW OF CORONA DISCHARGE REACTION CHAMBER ...
Страница 29: ...28 ELECTRICAL INTERLOCK BOX SOLENOID VALVE ...
Страница 33: ...32 DRIVE MODULE WIRING FOR M 15 O2 P 20 O2 ...
Страница 34: ...33 DRIVE MODULE WIRING FOR CD 15 O2 CD 20 O2 ...