21
6. After the system has run for several minutes, make the final adjustments to the injector and/or SCFH gauge.
Shutdown Procedure:
Once the system has been installed, the entire skid can be turned ON and OFF from the ‘ON/OFF/AUTO’ switch or the
service disconnect box.
Note: Do not change air flow adjustments.
MAINTENANCE
Ozone Generator
A word of caution: There is extremely high voltage inside the ozone generator. If you suspect a problem, disconnect the
power to the unit at the service disconnect box or main electrical panel and immediately contact your ClearWater Tech
distributor. Inspect the ozone delivery line check valves daily for water seepage and replace the injector check valve
yearly.
• Clean the ozone generator cabinet air filters:
These filters must be cleaned regularly. Depending on the location of the unit, it may be necessary to clean the air
filters monthly. On the bottom of the cabinet are filter elements (see illustration below). These are air intake
elements for the cooling fans and may therefore require the most frequent cleaning. All elements may be cleaned
with soap and water and should be dried completely before reinstalling.
Note: In a clean environment, these
procedures may only need to be performed every three months. IMPORTANT: CLEAN THESE FILTERS
REGULARLY!
FAILURE TO DO SO WILL PROMOTE OVERHEATING AND WILL VOID THE WARRANTY!
• Check valves:
The system is equipped with two check valves: one at the ozone generator ozone outlet and one on the venturi
injector. Depending on water pressure, these check valves will be either Kynar
®
(up to 35 psi) or stainless steel
(over 35 psi). The purpose of these check valves is to prevent water from backing up into the ozone generator.
The Teflon
®
ozone delivery line(s) should be inspected regularly to insure water is not flowing back into the ozone
generator. Check valves should be replaced or rebuilt yearly or when a maintenance problem has occurred with
the air preparation system. Note: On a properly installed system, the only time it is possible for water to flow back
toward the ozone generator is during a system shutdown. Always inspect for water see
page during this tim
Fan
Cabinet Bottom Plate
Fingerguard
Fan Filter Element
(Pt # FA40)
Fan Filter Grill
(snaps on and off)
Содержание CD15/O2
Страница 8: ...7 M 15 02 UNIT DIAGRAM ...
Страница 9: ...8 CD15 02 UNIT DIAGRAM ...
Страница 10: ...9 P 20 02 UNIT DIAGRAM ...
Страница 11: ...10 CD 20 02 UNIT DIAGRAM ...
Страница 13: ...12 M 15 02 CD 15 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 14: ...13 P 20 2 CD 20 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 16: ...15 M 15 02 CD 15 02 INTERLOCK WIRING CONNECTIONS ...
Страница 17: ...16 P 20 2 CD 20 02 INTERLOCK WIRING CONNECTIONS ...
Страница 28: ...27 ENLARGED VIEW OF CORONA DISCHARGE REACTION CHAMBER ...
Страница 29: ...28 ELECTRICAL INTERLOCK BOX SOLENOID VALVE ...
Страница 33: ...32 DRIVE MODULE WIRING FOR M 15 O2 P 20 O2 ...
Страница 34: ...33 DRIVE MODULE WIRING FOR CD 15 O2 CD 20 O2 ...