29
OZONE GENERATOR TROUBLESHOOTING
PROBLEM/SYMPTOM
POSSIBLE CAUSE
SOLUTION
Unit does not turn on
No power to unit
Check breakers
Switch not turned on
Check switch
Blown fuse
Replace fuse on bottom of unit
Cover/door interlock not active
Check door interlock switch
replace cover
Incorrect wiring connections
Check wiring (see manual)
Unit does not stay on
Insufficient vacuum
Adjust injector vacuum, check pump, be
(should be -5 to -15 on SCFH gauge)
sure check valves are properly installed
Defective solenoid
Inspect and repair/replace if necessary
Defective check valve
Inspect and replace if necessary
Unit overheating
Clean fan filter, check fan
Unit cycles on and off
Overheating
Clean fan filter, check fan
Defective power
Check for constant power if not
timer controlled
Defective solenoid
Inspect and repair/replace if necessary
Individual drive indicator
No power to drive module
Check drive module (see illustration)
lights not on
Blown fuse or lamp
Replace fuse or lamp
Drive module burnt out
Replace drive module
Unit trips circuit breaker
Incorrect wiring
Check wiring (see manual)
Incorrect circuit breaker
Check and, if necessary, replace with
correct circuit breaker
You receive an electrical shock
Incorrect wiring
Check wiring (see manual)
upon touching the unit
Unit not grounded
Ground unit in accordance with local
codes
Unit has been flooded
Return unit for major service or
completely disassemble and clean
Water in unit or
Insufficient vacuum
Adjust injector vacuum
ozone delivery tubing
Defective check valve(s)
Replace check valve(s)
Excessive back pressure on check valve Back pressure not to exceed 40 psi -
if over 40 psi consult ClearWater Tech
distributor
Ozone smell present
Insufficient vacuum
Adjust injector vacuum
Loose internal fittings
Inspect and tighten fittings
Defective O-ring seals in
Check and replace if necessary
reaction chamber
Defective dielectrics
Check and replace if necessary
Defective reaction chamber
Check and replace if necessary
You suspect that no ozone
Drive module failure
Touch the bottom of the coil -
is being produced
replace if it is not warm
Dielectric failure
Inspect and replace if necessary
Содержание CD15/O2
Страница 8: ...7 M 15 02 UNIT DIAGRAM ...
Страница 9: ...8 CD15 02 UNIT DIAGRAM ...
Страница 10: ...9 P 20 02 UNIT DIAGRAM ...
Страница 11: ...10 CD 20 02 UNIT DIAGRAM ...
Страница 13: ...12 M 15 02 CD 15 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 14: ...13 P 20 2 CD 20 02 ENLARGED VIEW OF TUBING PLUMBING CONNECTIONS ...
Страница 16: ...15 M 15 02 CD 15 02 INTERLOCK WIRING CONNECTIONS ...
Страница 17: ...16 P 20 2 CD 20 02 INTERLOCK WIRING CONNECTIONS ...
Страница 28: ...27 ENLARGED VIEW OF CORONA DISCHARGE REACTION CHAMBER ...
Страница 29: ...28 ELECTRICAL INTERLOCK BOX SOLENOID VALVE ...
Страница 33: ...32 DRIVE MODULE WIRING FOR M 15 O2 P 20 O2 ...
Страница 34: ...33 DRIVE MODULE WIRING FOR CD 15 O2 CD 20 O2 ...