background image

W A R R A N T Y                                                    

i i i

 

Clear-Com has the right to inspect the equipment and/or installation or 
relevant packaging.  

NON-WARRANTY REPAIRS AND RETURNS

For items not under warranty, you must obtain an RMA by contacting the 
User Support Center. Clear-Com representatives will give you instructions 
and addresses for returning your equipment. 

You must pay all charges to have the equipment shipped to the support center 
and returned to you, in addition to the costs of the repair.  

EXTENDED WARRANTY

If you purchase an Extended Warranty, you are also given access free of 
charge to the User Support Center 24 hours a day, 7 days a week. 

You can purchase an extended warranty at any time during the first two years 
of ownership of the product. The purchase of an extended warranty extends to 
five years the warranty of any product offered with a standard two-year 
warranty.  The total warranty period will not extend beyond five years. Any 
purchase of an extended warranty provides 24 x 7 customer support in 
addition to the warranty immediately upon purchase of the warranty 
extension.   

Note

: Clear-Com does not offer warranty extensions on UHF wireless 

intercom systems, or on any product with a 1-year or 90-day warranty. 

SERVICE CONTRACT 

Clear-Com also offers service contracts that provide 24 x 7 telephone support, 
advance replacements, training, proactive maintenance, on-site visits, and no 
charge for repair or replacement of equipment. For more information, contact 
your authorized dealer, distributor, or sales representative.  

LIABILITY 

THE FOREGOING WARRANTY IS CLEAR-COM'S SOLE AND 
EXCLUSIVE WARRANTY. THE IMPLIED WARRANTY OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 
AND ANY OTHER REQUIRED IMPLIED WARRANTY SHALL EXPIRE 
AT THE END OF THE WARRANTY PERIOD. THERE ARE NO OTHER 
WARRANTIES (INCLUDING WITHOUT LIMITATION WARRANTIES 
FOR CONSUMABLES AND OTHER SUPPLIES) OF ANY NATURE 
WHATSOEVER, WHETHER ARISING IN CONTRACT, TORT, 
NEGLIGENCE OF ANY DEGREE, STRICT LIABILITY OR 
OTHERWISE, WITH RESPECT TO THE PRODUCTS OR ANY PART 
THEREOF DELIVERED HEREUNDER, OR FOR ANY DAMAGES 
AND/OR LOSSES (INCLUDING LOSS OF USE, REVENUE, AND/OR 

Содержание PS-702

Страница 1: ...PS 702 TWO CHANNEL POWER SUPPLY I N S T R U C T I O N M A N U A L CLEAR COM ENCORE...

Страница 2: ...engineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambridg...

Страница 3: ...m Input Rear Panel 2 2 Rack Mounting 2 2 System Checkout 2 3 Check Termination 2 3 Check Intercom Cable Resistance 2 3 Final Tests 2 4 MAINTENANCE 3 1 Introduction 3 1 Troubleshooting Tips 3 1 PS 702...

Страница 4: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y i i...

Страница 5: ...ey exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the appa...

Страница 6: ...equirements And thereby compliance with the requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules O...

Страница 7: ...or your communications needs DESCRIPTION The Clear Com PS 702 is a single rack space one or two channel intercom power supply which can provide 1 2 ampere 2 amperes peak during call signals and other...

Страница 8: ...nd long term shorts and overload conditions After the first few times a short or overload occurs the power supply will try to restore power after only 0 5 seconds If the short or overload persists or...

Страница 9: ...atically detect the actions of other power supplies during overloads and short circuits to restore power as quickly as possible MULTI CHANNEL REMOTE STATIONS MAINTAIN THE POWER LINE ISOLATION The RM 7...

Страница 10: ...line connected to the affected channel Its red short overload light should go out This indicates a short in that line Follow that intercom line connecting and disconnecting cables along the line until...

Страница 11: ...vidual channels are controlled with a combination of the program trim level and the program send levels on the channels This feed can be fed to either or both intercom lines 9 AUDIO ADJUST This contro...

Страница 12: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y 1 6...

Страница 13: ...nd sidetone nulls at remote stations 10 The intercom system should now be operating properly 11 Read the rest of this manual for further information INSTALLATION INTERCOM LINE CONNECTION The PS 702 pr...

Страница 14: ...system no other power supplies or powered main stations are in the system the termination switch on each channel of the PS 702 should be switched to on Simply toggle the rear panel switch labeled term...

Страница 15: ...r the location 3 Repeat for the other channels 4 Check resistance between chassis ground and pin 1 Using an ohmmeter measure the resistance from pin 1 on the main station or power supply to chassis gr...

Страница 16: ...n a channel It should read 26 30 volts 2 Test for proper operation of call signaling Activate the call signal on any belt pack or station The call lights on all other stations on that channel should i...

Страница 17: ...ource PS 702 has an internal power supply failure Unit requires servicing Red short overload light illuminated Short or overload on that channel due to a shorted or mis wired cable Remove cables one a...

Страница 18: ...ground System feedback acoustical Volume control at the remote station is set too high Adjust Channel unterminated Set the PS 702 termination switch for that channel to the on position A headset exten...

Страница 19: ...Power S upply Module Program Input Channel A Power Controller Channel A Voltage Sensor Channel A Current Sensor Channel B Power Controller Channel B Voltage Sensor Channel B Current Sensor Ch B Term C...

Страница 20: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y 3 4...

Страница 21: ...ty Line 70dBu Max Gain Program Input Party Line 16dB Min Gain Program Input Party Line 20dB Mains Power Input Voltage Range 100 240 VAC Input Frequency Range 50 60 Hz Input Power 60 VAC Output Voltage...

Страница 22: ...tch 2 Overload LEDs 1 Link indicator LED 1 Power indicator LED 1 Power switch Environmental 32 122o F 0 50o C Dimensions 19 in W x 1 75 in H x 7 5 in D 483 mm x 44 mm x 190 mm Weight 6 16 lbs 2 80 kg...

Страница 23: ...the majority of Clear Com products It is a visual indicator on a station lamp or LED used to attract the attention of an operator who has removed the headset Channel A channel is the line that connec...

Страница 24: ...to Point One path to one person Program Audio source that is fed into the intercom channels Program Interrupt Disconnects the audio source while the talk button on the main station is pushed IFB Remo...

Страница 25: ...ones and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have a limited warranty of three years All other Cl...

Страница 26: ...warranty period has expired the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty or Service Contract In these cases you will have access to tel...

Страница 27: ...y provides 24 x 7 customer support in addition to the warranty immediately upon purchase of the warranty extension Note Clear Com does not offer warranty extensions on UHF wireless intercom systems or...

Страница 28: ...ontrol of Clear Com including unreasonable or negligent operation abuse accident failure to follow instructions in the manual defective or improperly associated equipment attempts at modification and...

Отзывы: