background image

W A R R A N T Y

i i                                

period will be offered at no charge between 09:00 and 17:00 according to the 
customer’s local time zone.

In addition, for customers who purchase an Extended Warranty or Service 
Contract, 24-hour customer support is offered immediately upon purchase of 
such agreement. For more information, contact your authorized dealer, 
distributor, or sales representative.

Instructions for reaching Clear-Com’s User Support Centers are given below.

Americas and Asia-Pacific Headquarters California, United States

 Tel: 

+1.510.337.6600 Email: [email protected] 

Europe, Middle East, and Africa Headquarters Cambridge, United 
Kingdom

 Tel: +44 1223 815000 Email: [email protected] 

Canada Office Quebec , Canada

 Tel: +1 (450) 653-9669 

China Office Beijing Representative Office Beijing, P.R.China

 Tel: +8610 

65811360 / 65815577

Once the standard warranty period has expired, the User Support Center will 
continue to provide telephone support if you have purchased an Extended 
Warranty or Service Contract. In these cases, you will have access to 
telephone support 24 hours per day, 7 days per week.

WARRANTY REPAIRS AND RETURNS 

Before returning equipment for repair, contact a User Support Center to obtain 
a Return Material Authorization (RMA). Clear-Com representatives will give 
you instructions and addresses for returning your equipment. You must ship 
the equipment at your expense, and the support center will return the 
equipment at Clear-Com’s expense. 

For out-of-box failures, use the following contact information: 

Americas and Asia-Pacific Headquarters California, United States

 Tel: 

+1.510.337.6600 Email: [email protected] 

Europe, Middle East, and Africa Headquarters Cambridge, United 
Kingdom

 Tel: +44 1223 815000 Email: [email protected] 

Canada Office Quebec, Canada

 Tel: +1 (450) 653-9669 

China Office Beijing Representative Office Beijing, P.R.China

 Tel: +8610 

65811360 / 65815577

Содержание PS-702

Страница 1: ...PS 702 TWO CHANNEL POWER SUPPLY I N S T R U C T I O N M A N U A L CLEAR COM ENCORE...

Страница 2: ...engineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambridg...

Страница 3: ...m Input Rear Panel 2 2 Rack Mounting 2 2 System Checkout 2 3 Check Termination 2 3 Check Intercom Cable Resistance 2 3 Final Tests 2 4 MAINTENANCE 3 1 Introduction 3 1 Troubleshooting Tips 3 1 PS 702...

Страница 4: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y i i...

Страница 5: ...ey exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the appa...

Страница 6: ...equirements And thereby compliance with the requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules O...

Страница 7: ...or your communications needs DESCRIPTION The Clear Com PS 702 is a single rack space one or two channel intercom power supply which can provide 1 2 ampere 2 amperes peak during call signals and other...

Страница 8: ...nd long term shorts and overload conditions After the first few times a short or overload occurs the power supply will try to restore power after only 0 5 seconds If the short or overload persists or...

Страница 9: ...atically detect the actions of other power supplies during overloads and short circuits to restore power as quickly as possible MULTI CHANNEL REMOTE STATIONS MAINTAIN THE POWER LINE ISOLATION The RM 7...

Страница 10: ...line connected to the affected channel Its red short overload light should go out This indicates a short in that line Follow that intercom line connecting and disconnecting cables along the line until...

Страница 11: ...vidual channels are controlled with a combination of the program trim level and the program send levels on the channels This feed can be fed to either or both intercom lines 9 AUDIO ADJUST This contro...

Страница 12: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y 1 6...

Страница 13: ...nd sidetone nulls at remote stations 10 The intercom system should now be operating properly 11 Read the rest of this manual for further information INSTALLATION INTERCOM LINE CONNECTION The PS 702 pr...

Страница 14: ...system no other power supplies or powered main stations are in the system the termination switch on each channel of the PS 702 should be switched to on Simply toggle the rear panel switch labeled term...

Страница 15: ...r the location 3 Repeat for the other channels 4 Check resistance between chassis ground and pin 1 Using an ohmmeter measure the resistance from pin 1 on the main station or power supply to chassis gr...

Страница 16: ...n a channel It should read 26 30 volts 2 Test for proper operation of call signaling Activate the call signal on any belt pack or station The call lights on all other stations on that channel should i...

Страница 17: ...ource PS 702 has an internal power supply failure Unit requires servicing Red short overload light illuminated Short or overload on that channel due to a shorted or mis wired cable Remove cables one a...

Страница 18: ...ground System feedback acoustical Volume control at the remote station is set too high Adjust Channel unterminated Set the PS 702 termination switch for that channel to the on position A headset exten...

Страница 19: ...Power S upply Module Program Input Channel A Power Controller Channel A Voltage Sensor Channel A Current Sensor Channel B Power Controller Channel B Voltage Sensor Channel B Current Sensor Ch B Term C...

Страница 20: ...P S 7 0 2 T W O C H A N N E L P O W E R S U P P L Y 3 4...

Страница 21: ...ty Line 70dBu Max Gain Program Input Party Line 16dB Min Gain Program Input Party Line 20dB Mains Power Input Voltage Range 100 240 VAC Input Frequency Range 50 60 Hz Input Power 60 VAC Output Voltage...

Страница 22: ...tch 2 Overload LEDs 1 Link indicator LED 1 Power indicator LED 1 Power switch Environmental 32 122o F 0 50o C Dimensions 19 in W x 1 75 in H x 7 5 in D 483 mm x 44 mm x 190 mm Weight 6 16 lbs 2 80 kg...

Страница 23: ...the majority of Clear Com products It is a visual indicator on a station lamp or LED used to attract the attention of an operator who has removed the headset Channel A channel is the line that connec...

Страница 24: ...to Point One path to one person Program Audio source that is fed into the intercom channels Program Interrupt Disconnects the audio source while the talk button on the main station is pushed IFB Remo...

Страница 25: ...ones and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have a limited warranty of three years All other Cl...

Страница 26: ...warranty period has expired the User Support Center will continue to provide telephone support if you have purchased an Extended Warranty or Service Contract In these cases you will have access to tel...

Страница 27: ...y provides 24 x 7 customer support in addition to the warranty immediately upon purchase of the warranty extension Note Clear Com does not offer warranty extensions on UHF wireless intercom systems or...

Страница 28: ...ontrol of Clear Com including unreasonable or negligent operation abuse accident failure to follow instructions in the manual defective or improperly associated equipment attempts at modification and...

Отзывы: