8
SPECIFICATIONS:
Rotomolded Body:
Vacuum:
VAC Shutoff:
Waterlift:
Pump:
Heat:
Heater:
Wand:
Weight:
Dimensions:
Lifetime Warranty
One, 3-stage
Ball Float
137”
400 PSI, positive displacement, adjustable
212º F, Maximum
2000 Watts
Stainless steel, single bend, two tip
100 lbs.
18W x 38L x 34.5H (inches)
TROUBLE SHOOTING:
IF THIS OCCURS
CHECK THIS
NO SPRAY
PUMP DOES NOT RUN
Solution tank is empty, or filter is plugged.
Clogged spray tip.
Pump not running.
Valve on wand not operating.
Solution hose not completely connected to hose or to machine.
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
This pump motor runs on AC voltage, so it should start running as soon as you
turn on the switch. If the pump motor does not start running, check the wiring
to the switch and to the motor. Check the switch to see if it is ‘open.’
Debris is plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum lid is not closed completely or is damaged.
Ball in the float is blocking air flow. Turn off the vacuum so the ball will drop down.
No power to motor. Does the switch light up? If not, the switch may be bad or
there may be no power getting to the switch. Check wiring connections.
Test the switch.
Test the vacuum motor.
Spraying for too long will significantly drop the heat. Try spraying for 8 - 10 seconds,
or about three strokes.
Heat exchanger needs to be flushed.
Wrong tool being used. Too much water passing through. Longer hose or larger
diameter hose, than standard.
Heat is not turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the heat switch - check wiring for ‘opens’.
No power out of heat switch. Replace switch.
Call your distributor for additional help.
MAXX- 400