background image

 

Pro

OX

 

7000

SXT

 

Installation

 

&

 

Startup

 

Guide

 

Page

 

3

            

www.cleanwaterstore.com

 

    

Rev

 

030514

 

Pre

Installation

 

1.

 

Review

 

your

 

packing

 

list

 

and

 

make

 

sure

 

you

 

have

 

received

 

all

 

the

 

parts

 

before

 

beginning

 

installation.

 

2.

 

If

 

you

 

are

 

going

 

to

 

be

 

turning

 

off

 

the

 

water

 

to

 

the

 

house

 

and

 

you

 

have

 

an

 

electric

 

water

 

heater,

 

shut

 

off

 

the

 

power

 

to

 

the

 

water

 

heater

 

before

 

beginning

 

installation

 

in

 

case

 

water

 

heater

 

is

 

accidentially

 

drained.

 

3.

 

Pick

 

a

 

suitable

 

location

 

for

 

your

 

filter

 

system

 

on

 

a

 

dry

 

level

 

spot

 

where

 

it

 

won’t

 

be

 

exposed

 

to

 

freezing

 

temperatures.

   

A

 

minimum

 

of

 

20

 

PSI

 

is

 

required.

  

Maximum

 

pressure

 

is

 

90

 

PSI.

 

4.

 

Get

 

all

 

of

 

your

 

plumbing

 

parts

 

together

 

before

 

beginning

 

installation.

  

Installation

 

typically

 

takes

 

3

 

to

 

5

 

hours.

  

However

 

after

 

installation

 

the

 

Pro

OX

 

Pro

OX

 

Filter

 

must

 

be

 

allowed

 

to

 

run

 

through

 

a

 

complete

 

backwash

 

and

 

rinse

 

cycle.

   

5.

 

After

 

the

 

system

 

is

 

installed

 

and

 

running,

 

your

 

water

 

may

 

be

 

discolored,

 

or

 

full

 

of

 

sediment

 

or

 

rust,

 

particularly

 

if

 

this

 

is

 

older

 

or

 

corroded

 

piping.

  

Typically

 

this

 

clears

 

up

 

over

 

a

 

day

 

or

 

two.

 

 

Best

 

Practices

 

for

 

Piping

 

&

 

Drain

 

Installation

 

1.

 

See

 

typical

 

installation

 

(see

 

Fig

 

2).

   

The

 

Pro

OX

 

filter

 

is

 

installed

 

after

 

the

 

pressure

 

tank.

  

If

 

you

 

are

 

also

 

installing

 

a

 

water

 

softener,

 

install

 

the

 

softener

 

after

 

the

 

Pro

OX

 

filter.

 

2.

 

Make

 

sure

 

to

 

follow

 

to

 

connect

 

the

 

in

 

pipe

 

to

 

the

 

Fleck

 

7000

SXT

 

inlet

 

and

 

the

 

outlet

 

to

 

the

 

outlet

 

(see

 

Fig

 

2).

 

As

 

you

 

face

 

the

 

Fleck

 

7000

SXT

 

control

 

from

 

the

 

front,

 

the

 

water

 

enters

 

on

 

the

 

right

 

and

 

exits

 

on

 

the

 

left.

  

From

 

the

 

back

 

(see

 

Fig

 

2)

 

the

 

water

 

enters

 

on

 

the

 

left.

  

The

 

inlet

 

and

 

outlet

 

are

 

attached

 

to

 

the

 

bypass

 

valve

 

which

 

is

 

marked

 

with

 

arrows

 

as

 

well.

 

3.

 

Make

 

sure

 

there

 

is

 

a

 

working

 

gate

 

or

 

ball

 

valve

 

before

 

the

 

Fleck

 

7000

SXT

 

Pro

OX

 

filter

 

and

 

also

 

one

 

after

 

as

 

shown

 

in

 

the

 

diagram

 

Fig

 

2.

   

The

 

pressure

 

gauges

 

are

 

optional

 

and

 

perhaps

 

not

 

necessary

 

but

 

a

 

hose

 

bib

 

(which

 

is

 

a

 

faucet

 

that

 

you

 

can

 

attach

 

a

 

garden

 

hose

 

to)

 

is

 

strongly

 

recommended

 

after

 

the

 

Pro

OX

 

filter

 

before

 

the

 

second

 

ball

 

valve.

  

This

 

makes

 

it

 

easy

 

to

 

rinse

 

your

 

new

 

Pro

OX

 

filter

 

on

 

start

up

 

and

 

gives

 

you

 

a

 

place

 

to

 

test

 

the

 

water

 

before

 

it

 

enters

 

your

 

household

 

plumbing.

   

4.

 

If

 

you

 

will

 

be

 

using

 

copper

 

piping,

 

do

 

not

 

sweat

 

the

 

copper

 

pipe

 

directly

 

on

 

to

 

the

 

Fleck

 

7000

SXT

 

control

 

valve.

  

Avoid

 

heating

 

up

 

the

 

Fleck

 

7000

SXT

 

control

 

valve

 

plastic

 

with

 

the

 

torch.

 

5.

 

You

 

do

 

not

 

need

 

unions

 

to

 

install

 

your

 

Fleck

 

7000

SXT

 

control.

  

If

 

you

 

need

 

to

 

remove

 

it,

 

the

 

Fleck

 

7000

SXT

 

has

 

quick

release

 

couplings

 

that

 

make

 

it

 

easy

 

to

 

put

 

the

 

Pro

OX

 

Pro

OX

 

filter

 

on

 

by

pass

 

and

 

remove

 

the

 

filter

 

system

 

from

 

the

 

piping.

 

Содержание PRO-OX 7000-SXT

Страница 1: ...g iron free water for many years Please review this start up guide entirely before beginning to install your system and follow the steps outlined for best results PRO OX MEDIA CONTAINS DUST USE PAPER MASK AND VENTILATE AREA TO AVOID BREATHING DUST DURING INSTALLATION Questions Call us toll free 1 888 600 5426 or 1 831 462 8500 Email us support cleanwaterstore com See more information on our websit...

Страница 2: ... Media Funnel Use 6 Fig 4 Fleck 7000 Bypass and Pipe Connectors 7 Fig 5 Fleck 7000 Bypass Knobs 7 Fig 6 Stainless Steel Backwash Drain Flow Control 8 Maintaining Your Pro OX Filter System 10 Troubleshooting the Pro OX 7000 Iron Filter System 11 What to Do If Your Filter Tank Does Not Sit Level on the Floor 11 Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide 11 User Programming ...

Страница 3: ...led 1 Media funnel In addition each system comes with the following depending on the model ordered 1 0 Cubic Foot Pro OX Quantity Description 1 12 lbs Gravel 2 cubic foot boxes of Pro OX filter media 1 5 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 3 cubic foot boxes of Pro OX filter media 2 0 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 4 cubic foot boxes of Pro OX filter medi...

Страница 4: ... you are also installing a water softener install the softener after the Pro OX filter 2 Make sure to follow to connect the in pipe to the Fleck 7000 SXT inlet and the outlet to the outlet see Fig 2 As you face the Fleck 7000 SXT control from the front the water enters on the right and exits on the left From the back see Fig 2 the water enters on the left The inlet and outlet are attached to the b...

Страница 5: ...th the drain tubing How Your Pro OX Filter System Works See Fig 1 In your Pro OX filter the water enters the top of the tank red arrows and flows down through the media and up the distributor tube blue arrows Iron and manganese in the water turns to an oxidized particle upon contact with the media and is trapped in the media During backwash the water flow is reversed and water flows down the distr...

Страница 6: ...g 2 Typical Pro OX piping installation with ball valve and hose bib after the filter Filter strainer is optional and useful if there is sand or grit in the water The 25 1 micron filter after is optional and used when there is very fine sediment or colloidal particles over 1 micron present ...

Страница 7: ...e and fill tank completely with water This will allow the Pro OX media to become activated and also sanitize the media It will also eliminate the need of purging the air out of the tank later 6 NOTE Regarding Teflon tape and pipe sealants It is OK to use Teflon tape and pipe sealant on the water pipe connector threads where you attach your pipes or plumbing to the Fleck 7000 DO NOT USE any Teflon ...

Страница 8: ...n the BY PASS position for now Fig 4 Fleck 7000 Bypass 1 Pipe Connectors 2 9 Lubricate the by pass valve o rings only on the pipe connectors with some vegetable oil or silicone grease and connect the bypass assembly to the Fleck 7000 control by sliding the bypass valve firmly into the body of the Fleck 7000 Once bypass is in far enough you will be able to easily insert the red connector clips DO N...

Страница 9: ...or 1 Note that it is desirable to be able to run the drain line into a bucket in order to test the backwash flow rate in the future This is why hard piping the drain line is discouraged however if you do use hard PVC piping for the drain line and you are able to remove the hard PVC drain piping and attach flexible tubing should you ever desire for testing purposes it is OK to use rigid PVC pipe fo...

Страница 10: ... important step clears out any foreign material that may be in pipes from the installation If you do not have a valve and hose bib installed after the Pro OX filter you will need to turn the water on inside the house to let the water run Use a bathtub or laundry sink or other fixture that does not have an aerator screen 20 Press the Extra Cycle button for a second or two which will start a manual ...

Страница 11: ...he backwash the Fleck 7000 will automatically advance to the rinse cycle 25 After the Pro OX filter has gone through the backwash and rinse press the Extra Cycle button and repeat the backwash and rinse This is the same procedure that needs to be done each time you add Pro OX media in the future that is the Pro OX media must be thoroughly backwashed and rinsed 26 Refer to your Fleck 7000 service m...

Страница 12: ...loor Your black filter tank base is not glued to the bottom of your tank Occasionally tank bases will become crooked during shipment If you find that that your tank does not sit level on the floor you can easily adjust it by holding the empty tank and rapping it on a concrete or solid floor once or twice in order to level it Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide This...

Страница 13: ...n the Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters cannot be viewed or set 1 Display Format Display Code DF Set display to GAL stands for U S Gallons or change to Liters or Cubic Meters if out of the U S Press the Extra Cycle button to go to the next step 2 Valve Type Display code VT Se...

Страница 14: ...rogramming and make adjustments if you want to the flow meter setting or Day Override setting Use the User Programming to avoid having to go through the Master Programming for quick changes to these settings below 1 Press the Up and Down buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Day Override Display Code DO Set to 1 to 14 based on your particular filter...

Страница 15: ... 3 Control Type Display Code CT Set to Fd This is the Meter Delayed option This tells the Fleck 7000 control to meter or keep track of the amount of water used but then wait until the pre set regeneration backwash and rinse cycles time typically in the middle of the night Press the Extra Cycle button 4 Unit Capacity Display Code C Set to 30 Use this display to set the Unit Capacity This setting sp...

Страница 16: ...lay to set the various minutes of each cycle Some of the cycles will be set to 0 Do not set any of the cycles to Off Use the Up or Down arrows to change the setting to the desired setting Press the Extra Cycle button to accept the setting and move to the next parameter a B1 Backwash Set to 8 to 10 minutes b BD Brine Draw Set to 0 c B2 2nd Backwash Set to 0 for most applications d RR Rapid Rinse Se...

Отзывы: