background image

 

Pro

OX

 

7000

SXT

 

Installation

 

&

 

Startup

 

Guide

 

Page

 

7

            

www.cleanwaterstore.com

 

    

Rev

 

030514

 

8.

 

Make

 

sure

 

the

 

by

pass

 

valve

 

is

 

in

 

the

 

bypass

 

position

 

when

 

starting

 

the

 

installation.

   

Follow

 

the

 

IN

 

and

 

OUT

 

arrows

 

on

 

the

 

bypass

 

valve

 

and

 

control

 

valve

 

for

 

proper

 

connection

 

of

 

in

 

and

 

out

 

water

 

piping.

  

Leave

 

in

 

the

 

BY

PASS

 

position

 

for

 

now.

 

Fig.

 

4:

 

Fleck

 

7000

 

Bypass

 

(1)

 

&

 

Pipe

 

Connectors

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

9.

 

Lubricate

 

the

 

by

pass

 

valve

 

o

rings

 

only

 

on

 

the

 

pipe

 

connectors

 

with

 

some

 

vegetable

 

oil

 

or

 

silicone

 

grease

 

and

 

connect

 

the

 

bypass

 

assembly

 

to

 

the

 

Fleck

 

7000

 

control

 

by

 

sliding

 

the

 

bypass

 

valve

 

firmly

 

into

 

the

 

body

 

of

 

the

 

Fleck

 

7000.

  

Once

 

bypass

 

is

 

in

 

far

 

enough,

 

you

 

will

 

be

 

able

 

to

 

easily

 

insert

 

the

 

red

 

connector

 

clips.

  

DO

 

NOT

 

USE

 

PETROLEUM

 

GREASE

 

ON

 

ANY

 

PART

 

OF

 

THE

 

FLECK

 

7000

 

CONTROL

 

VALVE.

   

 

Fig.

 

5:

 

Fleck

 

7000

 

Bypass

 

Knobs

 

 
 
 
 
 
 
 
 

Содержание PRO-OX 7000-SXT

Страница 1: ...g iron free water for many years Please review this start up guide entirely before beginning to install your system and follow the steps outlined for best results PRO OX MEDIA CONTAINS DUST USE PAPER MASK AND VENTILATE AREA TO AVOID BREATHING DUST DURING INSTALLATION Questions Call us toll free 1 888 600 5426 or 1 831 462 8500 Email us support cleanwaterstore com See more information on our websit...

Страница 2: ... Media Funnel Use 6 Fig 4 Fleck 7000 Bypass and Pipe Connectors 7 Fig 5 Fleck 7000 Bypass Knobs 7 Fig 6 Stainless Steel Backwash Drain Flow Control 8 Maintaining Your Pro OX Filter System 10 Troubleshooting the Pro OX 7000 Iron Filter System 11 What to Do If Your Filter Tank Does Not Sit Level on the Floor 11 Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide 11 User Programming ...

Страница 3: ...led 1 Media funnel In addition each system comes with the following depending on the model ordered 1 0 Cubic Foot Pro OX Quantity Description 1 12 lbs Gravel 2 cubic foot boxes of Pro OX filter media 1 5 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 3 cubic foot boxes of Pro OX filter media 2 0 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 4 cubic foot boxes of Pro OX filter medi...

Страница 4: ... you are also installing a water softener install the softener after the Pro OX filter 2 Make sure to follow to connect the in pipe to the Fleck 7000 SXT inlet and the outlet to the outlet see Fig 2 As you face the Fleck 7000 SXT control from the front the water enters on the right and exits on the left From the back see Fig 2 the water enters on the left The inlet and outlet are attached to the b...

Страница 5: ...th the drain tubing How Your Pro OX Filter System Works See Fig 1 In your Pro OX filter the water enters the top of the tank red arrows and flows down through the media and up the distributor tube blue arrows Iron and manganese in the water turns to an oxidized particle upon contact with the media and is trapped in the media During backwash the water flow is reversed and water flows down the distr...

Страница 6: ...g 2 Typical Pro OX piping installation with ball valve and hose bib after the filter Filter strainer is optional and useful if there is sand or grit in the water The 25 1 micron filter after is optional and used when there is very fine sediment or colloidal particles over 1 micron present ...

Страница 7: ...e and fill tank completely with water This will allow the Pro OX media to become activated and also sanitize the media It will also eliminate the need of purging the air out of the tank later 6 NOTE Regarding Teflon tape and pipe sealants It is OK to use Teflon tape and pipe sealant on the water pipe connector threads where you attach your pipes or plumbing to the Fleck 7000 DO NOT USE any Teflon ...

Страница 8: ...n the BY PASS position for now Fig 4 Fleck 7000 Bypass 1 Pipe Connectors 2 9 Lubricate the by pass valve o rings only on the pipe connectors with some vegetable oil or silicone grease and connect the bypass assembly to the Fleck 7000 control by sliding the bypass valve firmly into the body of the Fleck 7000 Once bypass is in far enough you will be able to easily insert the red connector clips DO N...

Страница 9: ...or 1 Note that it is desirable to be able to run the drain line into a bucket in order to test the backwash flow rate in the future This is why hard piping the drain line is discouraged however if you do use hard PVC piping for the drain line and you are able to remove the hard PVC drain piping and attach flexible tubing should you ever desire for testing purposes it is OK to use rigid PVC pipe fo...

Страница 10: ... important step clears out any foreign material that may be in pipes from the installation If you do not have a valve and hose bib installed after the Pro OX filter you will need to turn the water on inside the house to let the water run Use a bathtub or laundry sink or other fixture that does not have an aerator screen 20 Press the Extra Cycle button for a second or two which will start a manual ...

Страница 11: ...he backwash the Fleck 7000 will automatically advance to the rinse cycle 25 After the Pro OX filter has gone through the backwash and rinse press the Extra Cycle button and repeat the backwash and rinse This is the same procedure that needs to be done each time you add Pro OX media in the future that is the Pro OX media must be thoroughly backwashed and rinsed 26 Refer to your Fleck 7000 service m...

Страница 12: ...loor Your black filter tank base is not glued to the bottom of your tank Occasionally tank bases will become crooked during shipment If you find that that your tank does not sit level on the floor you can easily adjust it by holding the empty tank and rapping it on a concrete or solid floor once or twice in order to level it Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide This...

Страница 13: ...n the Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters cannot be viewed or set 1 Display Format Display Code DF Set display to GAL stands for U S Gallons or change to Liters or Cubic Meters if out of the U S Press the Extra Cycle button to go to the next step 2 Valve Type Display code VT Se...

Страница 14: ...rogramming and make adjustments if you want to the flow meter setting or Day Override setting Use the User Programming to avoid having to go through the Master Programming for quick changes to these settings below 1 Press the Up and Down buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Day Override Display Code DO Set to 1 to 14 based on your particular filter...

Страница 15: ... 3 Control Type Display Code CT Set to Fd This is the Meter Delayed option This tells the Fleck 7000 control to meter or keep track of the amount of water used but then wait until the pre set regeneration backwash and rinse cycles time typically in the middle of the night Press the Extra Cycle button 4 Unit Capacity Display Code C Set to 30 Use this display to set the Unit Capacity This setting sp...

Страница 16: ...lay to set the various minutes of each cycle Some of the cycles will be set to 0 Do not set any of the cycles to Off Use the Up or Down arrows to change the setting to the desired setting Press the Extra Cycle button to accept the setting and move to the next parameter a B1 Backwash Set to 8 to 10 minutes b BD Brine Draw Set to 0 c B2 2nd Backwash Set to 0 for most applications d RR Rapid Rinse Se...

Отзывы: