Pro
‐
OX
7000
‐
SXT
Installation
&
Startup
Guide
Page
14
www.cleanwaterstore.com
Rev
030514
Master
Programming
Mode
(for
Flow
Sensor
type)
Perform
a
Master
Reset:
Unplug
the
Fleck
7000
from
the
electrical
wall
outlet.
Hold
the
Extra
Cycle
button
while
plugging
in
and
powering
up
the
unit.
This
resets
all
of
the
parameters
in
the
unit.
Enter
Master
Programming
Mode:
Set
the
Time
of
Day
display
to
12:01
P.M.
Press
the
Extra
Cycle
button
(to
exit
Setting
Time
of
Day
mode).
Then
press
and
hold
the
Up
and
Down
buttons
together
until
the
programming
icon
replaces
the
service
icon
and
the
Display
Format
screen
appears.
Note,
that
when
the
Master
Programming
Mode
is
entered,
all
available
option
setting
displays
may
be
viewed
and
set
as
needed.
Depending
on
current
option
settings,
some
parameters
cannot
be
viewed.
1.
Display
Format
(Display
Code
DF):
Set
display
to
GAL
(stands
for
U.S.
Gallons),
or
change
to
Liters
or
Cubic
Meters
if
out
of
the
U.S.
Press
the
Extra
Cycle
button
to
go
to
the
next
step.
2.
Valve
Type
(Display
code
VT):
Set
to
DF2b.
This
means
it
is
set
for
standard
Down
‐
flow
mode,
similar
to
a
water
softener
so
we
can
take
advantage
of
the
flow
meter
in
this
Fleck
7000
5
‐
cycle
valve,
but
we
won’t
be
using
all
the
5
cycles
that
the
water
softeners
use.
Press
the
Extra
Cycle
button
to
go
to
the
next
step.
3.
Control
Type
(Display
Code
CT):
Set
to
Fd.
This
is
the
Meter
Delayed
option.
This
tells
the
Fleck
7000
control
to
meter
or
keep
track
of
the
amount
of
water
used,
but
then
wait
until
the
pre
‐
set
regeneration
(backwash
and
rinse
cycles)
time,
typically
in
the
middle
of
the
night.
Press
the
Extra
Cycle
button.
4.
Unit
Capacity
(Display
Code
C):
Set
to
30.
Use
this
display
to
set
the
Unit
Capacity.
This
setting
specifies
the
treatment
capacity
of
the
unit.
Since
we
are
not
using
this
for
softening,
where
the
capacity
of
the
softening
resin
can
be
accurately
defined,
30
is
a
number
we
can
start
with.
This
can
be
set
higher
or
lower
later
which
will
allow
the
meter
to
backwash
more
or
less
frequently
based
on
the
capacity.
Press
the
Extra
Cycle
button.
5.
Feed
water
Hardness
(Display
Code
H):
Set
to
10
to
20
.
This
is
the
feed
water
hardness
that
allows
the
meter
to
calculate
the
number
of
gallons
between
backwashes.
It
is
a
little
meaningless
for
filter
valves,
and
is
designed
for
water
softeners
which
remove
calcium
hardness
in
grains
per
gallons.
However,
if
you
set
it
to
20,
to
start
with,
you
will
later
see
the
number
of
gallons
between
cycles
when
you
are
finished
programming
based
on
your
size
of
system.
It
is
not
that
critical,
because
you
want
the
filter
to
backwash
once
a
week
or
every
few
days
based
on
the
type
of
filter
system
you
have,
by
setting
the
Day
Over
‐
Ride.
6.
Reserve
Selection
(Display
Code
RS):
Set
to
SF.
It
is
not
relevant
to
filter
control
valves.
7.
Safety
Factory
(Display
Code
SF):
Set
to
0.