5700-E Softener Installation & Startup Guide
Page 22
www.cleanwaterstore.com
Rev 091514
Restore Factory Settings
Hold the Regen button while plugging in the power supply to the unit. After the
unit has powered up release Regen button.
Next press the Regen
button again to select no
next to reset.
Using the down arrow,
scroll to yes.
Hitting the Gear will begin
resetting the unit.
Power Outage Memory.
During a loss of power, all program settings will be stored in permanent memory.
The current valve position, cycle step and time of day are all stored as well, but
upon power up a reset of the current time will be necessary.
If the unit were to lose power during a regeneration stage, the valve will return
back to its prior position when the outage occurred.
The unit will take 4 -5 minutes
to reset back to that position.