5700-E Softener Installation & Startup Guide
Page 13
www.cleanwaterstore.com
Rev 091514
Normal Operation
Time Mode
: Home screen will
display days and hours left until the
unit regenerates.
Meter Mode
: Meter mode tracks the number of gallons used instead of
regenerating on a specific time. In
this mode immediate regeneration
will occur once the unit hits its
target calculated number of gallons
based on hardness settings.
Timed Meter Mode
: Timed Meter Mode tracks the number gallons used, like the
Meter Mode, but waits until its set
time to regenerate instead of
immediately. A buffer period is
factored in to prevent you from
running out of soft water. The
water droplet to the right of Current Time signifies the unit tracking water flow.
We recommend T for the operation of your softener, to backwash by gallons, but
also with a day limit. Change the setting, then press the down arrow to proceed to
the next step.