instructions for use
make sure the air is dry, otherwise the blasting agent will
form lumps
Set the desired working pressure on the regulator. The compressed air set
will be displayed on the Manometer.
max. 7 bar, recommended is 2
−
4 bar
air consumption about 150 l / min at 5 bar
Fill blasting agent into the container
make sure the blasting agent is dry
The lid (15) is to be unscrewed when blasting agent is filled into the
container. Using a funnel, fill the container with blasting agent up to approx.
one finger’s width under the rising pipe in the middle of the container.
Close the container.
You can begin work by using the button on the blasting gun
Blasting stops by releasing the button
Once work has been finished, the unit must be disconnected from the
compressed air supply.
during blasting, goggles (face mask), dust mask, breathing
mask and gloves are to be worn
5.6.5 blasting agent
As a rule, the following two agents can be delivered ex stock:
•
eks 10:
strongly abrasive, fast removing agent – leaves a rough surface
•
mgk 10:
has a more polished effect – leaves a shiny surface
5.7 cOnnecting up the autOmatic electrOlyte Feed On
clean marker p and clean marker tp
• plug the black plug belonging to the pump tubing set into the connecting
socket (17)
• push the acid tubing so far into the stainless steel connection of the bulk
-
head stuffing box (20), that it cannot fall out by itself - press the safety ring
(21) at the same time, hold it firmly and push the tube into the opening
• push the 3 - pole plug in the driving power connection (16) and screw it up
tightly
• unwind as much as you need of the acid tube from the roller (18) and tip it
into the electrolyte container (19)
Liquid will only be fed when the button on the cleaning head is pressed.
When pumping, open the acid container a little so that negative pressure
cannot build up when the liquid is sucked up and damage the pump. On
all Clean Markers equipped with pump the electrolyte is sucked up directly
from an external 5 / 10 litre cannister, a bottle or a wide - necked container.
The acid tubing must therefore be hung into the electrolyte container.
Operation Manual Clean Marker Brush
−