MAXIHEAT DEFAULT FLUE KIT
IMPORTANT
This drawing is meant as a guide only. Heater should be installed by a qualified
person whose work conforms to local council VBR Regulations, ASA Standards
and manufacturer’s recommendations.
COWL
ROOF FLASHING
RAFTER
MINIMUM DISTANCE
FROM OUTER CASING
TO ANY COMBUSTIBLE
MATERIAL = 25mm
ANGLE SUPPORT
BRACKET FOR
OUTER CASING
JOIST
CERAMIC
SPACERS
MINIMUM DISTANCE FROM
OUTER CASING TO ANY
COMBUSTIBLE
MATERIAL = 25mm
DO NOT USE CEILING
PLATE TO SUPPORT
CASINGS
HEATER FLUE COLLAR
CEILING PLATE FIXED WITH
CERAMIC SPACERS
150mm OF OUTER CASING
PROTRUDING INTO ROOM
CEILING
INNER AND OUTER CASING SCREWED
OR POP RIVETED TOGETHER
1000mm
MINIMUM
OUTER CASING
INNER CASING
ACTIVE
FLUE
INNER AND OUTER
CASINGS HAVE
VENTILATION SLOTS
AT THE TOP
SIDE VIEW OF
ANGLE SUPPORT BRACKET
50mm FROM TOP OF CASINGS
TO TOP OF ACTIVE LENGTH
ACTIVE LENGTHS
SCREWED OR POP
RIVETED TOGETHER
BRACKET
SCREWED
TO OUTER
CASING
AND JOISTS
COWL SECURED
ONTO OUTER
CASING