Clayton Steam Generator model EO-100-1
PAGE 66 / 70
Instruction Manual, doc.nr.: MAN18206 Rev A PSC
CHAPTER 11 :
INSTRUCTION AND OPERATION FOR PRESSURE VESSELS
11.1
DESCRIPTION OF PRESSURE VESSEL
The wording “pressure equipment” in this document is used for steam vessels and collectors, pressurized
water and/or steam accumulators, return receivers and pressurized hot water drums where the water can flash
into steam when released directly to the atmosphere, any of them operated at a pressure exceeding 0,5 barg,
with no limitations on size when their volume is over 1 liter.
11.1.1
SCOPE - APPLICATION.
The instructions of this manual are only applicable for the pressure equipment supplied or manufactured by
Clayton of Belgium.
The vessel serves as a recipient that collects pressurized water, steam or a mixture of both, in which the
separation of steam and water occurs or in which the pressurized condensates return.
The operating conditions must fall within the specified limits defined in the specifications and/or drawings.
The instructions contained in this document should be read and used together with the specific operation,
maintenance and safety instructions applicable to steam and/or hot water and/or high pressure units.
Consequently, these instructions can also be applied to pipe connections and tubes to the users of the
pressure equipment.
11.1.2
SPECIFICATIONS. AND DESIGN DATA
Please refer to final QC documents :
11.2
TRANSPORT, HANDLING AND STORAGE.
The pressure equipment shall not be transported under pressure or any loading.
The lifting capacity of the hoist should be checked before lifting.
For handling, transport and assembly suitable lifting tools and devices shall be used to avoid any deformation
or any damage to any of the connection points, joints, flanges or installed equipment and devices. The
equipment shall never be lifted from the casing or the connecting flanges or piping.
The pressure equipment shall be supported by its specific designed supporting legs and/or by a wooden
structure designed for that purpose. Point loads on the body can lead to serious deformation.
Transport and storage below the freezing point
(0°C)
are not allowed.
(Freezing risk of un-drainable
remaining water in the pressure equipment).