Clayton Steam Generator model EO-100-1M
PAGE 26 / 70
Instruction Manual, doc.nr.: MAN18206 Rev A PSC
TROUBLE
POSSIBLE CAUSE
SOLUTION
Noisy water pump operation
- Waterpump
discharge
snubber not working properly
- Flexible
coupling
loose
between motor and pump
- Hotwell not mounted at
proper height
- Worn bearings or lack of oil
in crankcase
- Restricted
heating
coil
causing
excessive
back
pressure
- Check and clean intake surge
chamber. Replace rubber
mould if necessary
- Tighten setscrews in flexible
coupling
- Install boosterpump
- Replace
bearings
if
necessary. Add oil to proper
level
- Check for scale formation in
heating coil (comparison of
feed press. with normal
value)
Steam pressure discharge gauge reaches
zero pressure
- Steam trap closed
- Pressure gauge defect
- Ensure
waterpump
is
discharging
at
normal
capacity
- Blowdown valve partially
open. Close blowdown valve
- Check for possible malfunc-
tioning of steam trap
- Replace pressure gauge
7.2
FUEL SYSTEM OIL FIRED UNITS
TROUBLE
POSSIBLE CAUSE
REMEDY
Fuel pressure to low
(stop generator immediately to avoid
dammage to oil pump)
- Fuel tank empty or supply
lines plugged
- Fuel pressure not adjusted
properly
- Air leak in supply line
causing loss of pressure
- Fuel pump failure
- Check level in fuel storage
tank.
- Check if all valves in supply
lines are opened.
- Adjust fuel pressure regulator
- Suction line must be air tight
and air pockets eliminated
- Replace fuel pump