41001452 Iss 06
4
ENSURE AIR OUTLET LOUVRES ARE NEAREST
TO THE DOOR APPERTURE.
3.1
Mounting
All units should be installed horizontally directly
over the door opening. It is recommended that the
air curtain is installed on the inside of the building,
within the open room space against a wall or
ceiling.
Care must be taken to allow complete free air
movement into the inlet grilles of the unit to ensure
correct working operation of the air curtain. The
discharge opening should be as close to the top of
the door as possible and cover the entire door
width.
Units can be mounted adjacent to each other to
cover the full door opening across wider
entrances.
The weight of the RAC0603 and RAC0604 is 8kg
The weight of the RAC1006 is 11.5kg
3.2
Electrical Installation
These units are suitable for connection to 230/240
Volt 50 Hz single phase supply.
The appliance shall be connected to the supply
via an appropriate switched fused double pole
isolator having a contact separation of greater
than 3mm. Test for correct operation and refit the
grille.
For connection to the mains supply it will be
necessary to remove the grille from the unit. It will
be necessary to connect the mains supply and the
lead from the controls prior to refitting the cover.
Wire in accordance to wiring diagrams.
For safety reasons, a sound earth connection
must always be made to the unit before it is put to
use. The unit should be wired in accordance with
IEE Regulations for the Electrical Equipment of
Buildings.
3.3
Installation
It is the sole responsibility of the installer to ensure
3. Installation Details
Fig.1 ceiling cutout for RAC0603 and RAC0604
Fig.2 ceiling cutout for RAC1006
Fig.3 Grille fixings detail