41001452 Iss 06
2
els will not work without the controller. See section
6.1 for more details.
1.5
RX Controller Location
It is essential the Controller is positioned in the
same room as the aircurtain. It should be where its
temperature will not be change with local effects.
Avoid:
•
Draughty places near windows or doors
•
Places near the aircurtain itself or any other
heat sources in the room
•
Places where the sun will shine on it
•
Places where it may get wet
1.6 Controller standard models
The RAC0603, RAC0604, RAC1006 heaters are
supplied with a remote controller. The remote con-
trol unit houses 3 double pole 20A rocker switches.
The heater can also be controlled remotely via BMS
or any controls with contact rated at 20A for
RAC0603, RAC0604 and 30A for RAC1006. The
controller is wired to the base unit via an appropri-
ate sized cable specified by the current IEE stand-
ard.
1.7
Clearance Distances
It is recommended that a minimum clearance of
100mm is allowed around the case and 55mm
above. The clearance allows for cable entry and
prevents combustible surfaces overheating.
The minimum mounting height (floor to grille) is 2m.
The maximum mounting height is 3m.
1. General Information
1.1
Introduction
The heaters are designed for discreet positioning in
a suspended ceiling or bulkhead in the doorways of
retail or commercial premises. Overall energy sav-
ing is likely when the heater is sited above a fre-
quently opened external door as the airstream can
prevent heat loss. Will fit a recess as shallow as
195mm.
3.3
Health and Safety
Sole liability rests with the installer to en-
sure that all site safety procedures are ad-
hered to during installation.
Sole liability rests with the installer to en-
sure that protective safety wear such as
hand, eye, ear and head protection is used
during installation of the product.
Do not rest anything especially ladders
against the product.
1.2
General
All installations must be in accordance with the reg-
ulations in force in the country of use.
These instructions must be handed to the user on
completion of the installation.
Installers and service engineers must be able to
demonstrate competence and be suitably qualified
in accordance with the regulations in force in the
country of use.
To ensure continued and safe operation it is recom-
mended that the appliance is serviced annually.
( See 7.1 )
The heater outlet / inlet must not be obstructed dur-
ing use.
1.3
Electrical Supply.
Electrical supply is 230/240V single phase, Neutral
and Earth. The maximum cable inlet size is 4mm².
It is recommended that the electrical supply to the
base unit in the heater is via an appropriate
switched isolator in accordance with the regulations
in force in the country of use and must be via a
fused isolator having a contact separation of greater
than 3mm on all poles.
There are no exceptions
.
BMS control, time switches, room thermostats and
door interlocks can be installed at the discretion and
responsibility of the installer.
All units must be wired in accordance with I.E.E reg-
ulations for the Electrical Equipment of Buildings
and the installer should ensure that a suitable isolat-
ing switch is connected in the mains supply.
1.4 Controller `RX` models
The RAC0603RX, RAC0604RX, RAC1006RX heat-
ers are supplied without a controller. The `RX` mod-
CONSORT
CRXSL
Wireless controller