RECOMMENDATIONS BEFORE OPERATION
The heater may only be used in open or at least well ventilated rooms.
IMPORTANT!
Be careful not to block the intake grille of the heater. Any work on the heater must be carried
out when the heater is cold and the power plug is disconnected. The socket must be
The socket outlet must have an effective grounding system. Never bring flammable or explosive materials
near the unit. The room where the appliance is used must be adequately ventilated and free of and the
absence of any residue of dust, gas or vapors that are flammable or toxic at high temperatures. Never fill up
with fuel while the appliance is in operation; any possible loss of fuel on the floor must be fuel on the floor
must be carefully wiped off. Do not allow the fan suction to attract paper, cloth, plastic, powders or any
other material that could clog or damage the unit. Never operate the generator without fuel: despite the
intervention of the control box, which stops the unit, running without fuel may cause the fuel pump to seize.
Use only the type of fuel indicated on the machine’s technical data plate.
N.B
. Do not add petrol or other solvents to the fuel; in the case of use at particularly low temperatures, use
fuel with additives that are readily available on the market.
Electrical connections :
Warning
Before starting up the machine, check that the connection voltage corresponds to that indicated on the
data sheet on board the machine.
-
The connection must be made in accordance with the standards and must be properly
grounded.
- Have a qualified electrician install a high-sensitivity differential circuit breaker, intervention at 30
mA or less.
- If necessary, it is possible to use extension cables with a cross-section of 1.5 mm2 for lengths up to
10 m. and 2.5 mm2 for lengths between 10 and 50 m.
In case of replacement of the original power supply cable, use a cable with an adequate cross-section and a
grounding conductor; the cable must have a continuous insulating coating suitable for use outdoors and in
closed areas. The cable must have a continuous insulating coating suitable for use outdoors and in enclosed
areas. A fume exhaust in accordance with the standards must be provided.
SWITCHING ON / OFF
Start-up (without room thermostat)
• Fill the fuel tank with fuel.
• Insert the plug into the socket (the red light comes on).
• Turn the ON/OFF switch to the
ON
position (the green light comes on and the fan starts).
• The automatic ignition cycle is started by the control box.
After a few seconds of automatic monitoring, the generator remains regularly in operation.
• If, due to some small irregularities, the unit stops and the
RESET
light is on, the
RESET
button must be
pressed to restart the ignition cycle.
Start-up (without room thermostat)
• The unit is already adapted to be connected to a room thermostat (optional).
• If necessary, the connection should be made using the socket provided for this purpose on the
electrical panel.
• After setting the room thermostat, turn the switch to the AUT position. To switch off the appliance,
use either the main switch or the room thermostat. In both cases, a correct cooling cycle of the
generator is guaranteed.
During normal operation of the machine, the
RESET
button flashes. In case of a malfunction, the
button remains lit for 10 seconds. Determine and solve the cause of the
If necessary, determine and solve the cause of the problem and reset the machine by pressing the
RESET
button.
Содержание CH 0022
Страница 6: ...6 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 Porte buse...
Страница 7: ...CHAUFFAGE FIOUL DIRECT 16 5kw 20kw 30kw 40kw 50kw 7 T te de combustion...
Страница 15: ...15 DIRECT DIESEL OIL HEATER 16 5kw 20kw 30kw 40kw 50kw Nozzle holder...
Страница 16: ...16 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 Combustion head...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ......
Страница 27: ......