Troubleshooting
Problem
Possible court
Possible solution
The motor won’t
start.
- Motor stop is “OFF”.
- The fuel tap is closed
- Choke is open.
- The fuel is empty.
- The fuel is polluted or old.
- The sparkplug is dirty
- The sparkplug is damaged.
- The generator is not placed
on an even surface
- The oil level is low
- Turn motor stop “ON”.
- Turn on fuel tap.
- Close choke.
- Fill up with fuel.
- Change and fill up with new fuel.
- Clean sparkplug.
- Change sparkplug.
- Lift the generator to a flat surface
to prevent it from switching off
automatically due to low oil level.
- Fill up or change oil.
The motor is
running but the
generator is not
providing any
current.
- The circuit breaker (3) is
“OFF”.
- Poor connections or cables.
- The device connected is not
working.
- Turn circuit breaker (3) “ON”.
- If using extension cable, change
it.
- Connect another device.
The generator is
running but is not
running all con-
nected devices.
- The generator is overloaded
- Short-circuit in one of the
devices connected
- The air filter is dirty.
- Disconnect one of connected
devices
- Disconnect one of the faulty
or short-circuited connected
devices
- Clean or change air filter.
Disposal
When disposing of product it should be done in accordance with local rules and
regulations. If you are unsure as to how to proceed please contact your local
council.
Содержание DQF2
Страница 5: ... EN GLI SH 10 9 13 12 8 11 14 15 16 17 18 19 21 20 ...
Страница 17: ...17 SV EN SK A 10 9 13 12 8 11 14 15 16 17 18 19 21 20 ...
Страница 29: ...29 NOR S K 10 9 13 12 8 11 14 15 16 17 18 19 21 20 ...
Страница 41: ...41 SUOM I 10 9 13 12 8 11 14 15 16 17 18 19 21 20 ...
Страница 51: ......