background image

 

 

T H E   C O N T I N U O U S   P O W E R   C O M P A N Y

 

Page 4 

TECHNICAL DESCRIPTION

he Digital Technology 

S Series

 

Continuous

 

Power System (CPS) is a revolutionary new 
concept in total power protection and 
management.  The 

S Series

 is a 

microprocessor-based UPS that now allows the user 
to set most of the control feature parameters.  By 
directly linking a personal computer to the 

S Series

 

RS232 port, frequency settings and operation, alarm 
signals, load switching, fan operation, etc. can all be 
programmed to meet specific application 
requirements. 
The 

S Series

 is a true on-line, continuous power 

UPS.  In the tradition of Clary products, the  

S Series

 generates the same high quality and 

proven reliability to provide the best power 
protection available for today’s critical applications. 
In keeping with state-of-the-art design, the power 
electronics are completely governed by an on-board 
microprocessor.  Given the powerful memory 
capability of today’s microcontrollers, this 
microprocessor has evolved the UPS into an all-in-
one complete power distribution and monitoring 
center.  Not only is your critical load insured of the 
most reliable and constant power available, but the 
user may now continuously track status of the 
supply components that keep the entire system 
operational.  Production downtime can now be 
virtually eliminated by knowing exactly what patterns 
the supply utility power maintains and by knowing 
exactly the condition and life expectancy of the 
battery reserve. 
Reference the block diagram for a simplified 
explanation of the system’s operation.  The AC utility 
source is connected to the power and micro-
electronics when the input switch is closed.  The 
input line is filtered, power factor corrected and 
rectified for enhanced performance without 
disturbing other equipment that may share the same 
utility circuit.  In 

S

 units, an input isolation 

transformer is added.  Output transformers, SNMP 
adapters and many other options are available. 
The microprocessor controls an 

Inverter Generator

 

that produces a low harmonic, AC sinewave for 
continuous power applications. 
When the input AC utility line fails, the battery circuit 
within this system takes over to ensure continuous 
power.   

Only after properly rated power is returned, does the 
microprocessor reconnect the input source back into 
the system. 
The microprocessor is directly tied to an external 
RS232 connector port.  This allows the user to 
monitor and even set some of the operating 
parameters.  With a simple link to a personal 
computer using the 

DT-UPS2

 software program, you 

can actually view, on your monitor, the event history 
of the power distribution system with the  

S Series

 unit as the central hub.  More sophisticated 

users may implement the optional SNMP package to 
accomplish full 

Network Power Management

BATTERY-DESCRIPTION 

 

Your system contains sealed, maintenance free 

lead acid batteries manufactured by Enersys,. It 
consists of six (6) NPX-25FR, 12 volt 5.0 ampere-
hour (AH) batteries. They are connected in series to 
form a 72 volt bus.  Batteries are charged with a 
constant current, half (0.5) amp charger.  The 
microprocessor controls the constant current 
charging until full charge requirements are met, then 
a periodic trickle charge is programmed to the 
battery. 
A low battery signal is generated during discharge 
when the terminal voltage reaches the point where 
the microprocessor determines there is 2 minutes 
left of battery reserve time.  This time can be 
changed through the RS232 communications port.  
The battery is protected by a system cutoff signal 
which is activated before the terminal voltage 
reaches an unsafe discharge point. 

WARNING:

 

Never attempt to service batteries, 

high voltage exists within the unit which could cause 
electrical shock. Servicing of batteries should be 
performed or supervised by personnel 
knowledgeable of batteries and the required 
precautions. Keep unauthorized personnel away 
from batteries. When replacing batteries use the 
same number and type. The battery pack has a 
keyed, polarity sensitive connector. Replace only 
with factory authorized replacement parts. 

Содержание S1500-601

Страница 1: ...ion is proprietary confidential and not to be disclosed disseminated or used except for the purpose provided by CLARY CORPORATION P N 510 14825 REV A PENDING 10 2006 CLARY SCIENTIFIC INC 150 E Hunting...

Страница 2: ...TS TITLE PAGE TABLE OF CONTENTS 2 INTRODUCTION 3 TECHNICAL DESCRIPTION 4 PACKAGING 6 PHYSICAL DESCRIPTION 7 SUMMARY OF INDICATORS AND CONTROLS 10 INSTALLATION 11 OPERATION 12 SIGNALS AND INTERFACING 1...

Страница 3: ...in accordance with the directions presented Any and all equipment modifications must be authorized in writing by Clary Corporation and executed by appropriately assigned qualified personnel The electr...

Страница 4: ...are available The microprocessor controls an Inverter Generator that produces a low harmonic AC sinewave for continuous power applications When the input AC utility line fails the battery circuit wit...

Страница 5: ...UTILITY INPUT INPUT ISOLATION TRANSFORMER BYPASS LINE EMERGENCY CUTOFF SWITCH VOLTAGE WINDOW DETECTOR COMMON MODE CHOKE RECTIFIER CHARGER POWER FACTOR CORRECTOR DC RAILS MICROPROCESSOR CONTROLLER AC I...

Страница 6: ...cking material for future use Take extra precaution when removing or returning it to the box Because this unit contains a battery it can be quite heavy Never attempt to unpack the equipment unassisted...

Страница 7: ...t the bottom with a brief identification In the next section a complete explanation of all numbered items will be enhanced to ensure you have a full understanding of the operation of this system Visua...

Страница 8: ...tery Level Charge discharge indicators 11 LOAD II ACKNOWLEDGE INDICATOR 5 Load Level Output capacity indicators 12 Alarm Silent Test Dual function switch 6 Cold Start DC start switch 13 ALARM SILENT T...

Страница 9: ...ut line protection 20A 250V 20 RS232 Computer communications signals 17 DC INPUT Auxiliary battery connector for 72VDC system 21 IDENTIFICATION LABEL 18 120VAC OUTPUT System output 22 SNMP Optional Sl...

Страница 10: ...minals at the rear panel SNMP Optional A slot available to install an interface card to provide system network management Alarm Silent Test A momentary push button switch that controls two different f...

Страница 11: ...em remains cooler during operation there is less stress on the batteries and the internal electronics The air inlets vents and fan should not be obstructed or blocked in any way The more breathing spa...

Страница 12: ...Mode DC Start Operation Cold Start If no utility power is available at the time backup power is required the unit may be started to accomplish abbreviated tasks The limitations of the battery prevent...

Страница 13: ...own by applying a 5 to 12V signal across the appropriate pins Contact the factory for configuration details RS232 is a true computer communications signal port The open collector signal outputs can be...

Страница 14: ...y 1 Duplex 5 15R Cooling Low Velocity Temperature Controlled Reversible Forced Air Dimensions HxWxD in cm 14 1 36 x 6 9 17 5 x 21 53 Weight lbs kg 80 36 DESIGN Standard Features Power Factor Corrected...

Страница 15: ...mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The follo...

Страница 16: ...process any unit returned to the factory In consulting the factory always have the unit model number and serial number at hand This information is located on the identification label and is essential...

Страница 17: ...ssued Return Material Authorization RMA by calling 800 442 CLARY All transportation charges prepaid clearly tagged stating the nature of trouble experienced and the disposition of the equipment after...

Отзывы: