background image

 

 

T H E   C O N T I N U O U S   P O W E R   C O M P A N Y

 

Page 16 

SERVICE AND REPAIR

our 

S Series 

UPS is backed by one of the 

finest customer service teams available.  
Write or call them at any time to obtain more 
information about your unit. 

NOTE:  ALL SERVICE AND REPAIRS ARE TO BE 
CONDUCTED BY CLARY CORPORATION. 

Clary Corporation 
150 E. Huntington Drive 
Monrovia, CA  91016 
1-800-551-6111 

If a problem should occur, it is important that you 
obtain a Return Material Authorization (RMA) 
number from the Service Department to process any 
unit returned to the factory.  In consulting the factory, 
always have the unit model number and serial 
number at hand.  This information is located on the 
identification label and is essential in retrieving your 
unit’s performance and history record. 

The RMA number issued to you should appear on 
the outside of the carton, if the unit is returned, or on 
any correspondence regarding your unit.  When 
shipping a unit back to the factory, try to use the 
original packing container and shipping materials.  
The Service Department cannot take responsibility 
for any unit damaged in return shipment.  All units 
must be returned prepaid to: 

Clary Corporation 
Service Center 
150 E. Huntington Drive 
Monrovia, CA  91016

Содержание S1500-601

Страница 1: ...ion is proprietary confidential and not to be disclosed disseminated or used except for the purpose provided by CLARY CORPORATION P N 510 14825 REV A PENDING 10 2006 CLARY SCIENTIFIC INC 150 E Hunting...

Страница 2: ...TS TITLE PAGE TABLE OF CONTENTS 2 INTRODUCTION 3 TECHNICAL DESCRIPTION 4 PACKAGING 6 PHYSICAL DESCRIPTION 7 SUMMARY OF INDICATORS AND CONTROLS 10 INSTALLATION 11 OPERATION 12 SIGNALS AND INTERFACING 1...

Страница 3: ...in accordance with the directions presented Any and all equipment modifications must be authorized in writing by Clary Corporation and executed by appropriately assigned qualified personnel The electr...

Страница 4: ...are available The microprocessor controls an Inverter Generator that produces a low harmonic AC sinewave for continuous power applications When the input AC utility line fails the battery circuit wit...

Страница 5: ...UTILITY INPUT INPUT ISOLATION TRANSFORMER BYPASS LINE EMERGENCY CUTOFF SWITCH VOLTAGE WINDOW DETECTOR COMMON MODE CHOKE RECTIFIER CHARGER POWER FACTOR CORRECTOR DC RAILS MICROPROCESSOR CONTROLLER AC I...

Страница 6: ...cking material for future use Take extra precaution when removing or returning it to the box Because this unit contains a battery it can be quite heavy Never attempt to unpack the equipment unassisted...

Страница 7: ...t the bottom with a brief identification In the next section a complete explanation of all numbered items will be enhanced to ensure you have a full understanding of the operation of this system Visua...

Страница 8: ...tery Level Charge discharge indicators 11 LOAD II ACKNOWLEDGE INDICATOR 5 Load Level Output capacity indicators 12 Alarm Silent Test Dual function switch 6 Cold Start DC start switch 13 ALARM SILENT T...

Страница 9: ...ut line protection 20A 250V 20 RS232 Computer communications signals 17 DC INPUT Auxiliary battery connector for 72VDC system 21 IDENTIFICATION LABEL 18 120VAC OUTPUT System output 22 SNMP Optional Sl...

Страница 10: ...minals at the rear panel SNMP Optional A slot available to install an interface card to provide system network management Alarm Silent Test A momentary push button switch that controls two different f...

Страница 11: ...em remains cooler during operation there is less stress on the batteries and the internal electronics The air inlets vents and fan should not be obstructed or blocked in any way The more breathing spa...

Страница 12: ...Mode DC Start Operation Cold Start If no utility power is available at the time backup power is required the unit may be started to accomplish abbreviated tasks The limitations of the battery prevent...

Страница 13: ...own by applying a 5 to 12V signal across the appropriate pins Contact the factory for configuration details RS232 is a true computer communications signal port The open collector signal outputs can be...

Страница 14: ...y 1 Duplex 5 15R Cooling Low Velocity Temperature Controlled Reversible Forced Air Dimensions HxWxD in cm 14 1 36 x 6 9 17 5 x 21 53 Weight lbs kg 80 36 DESIGN Standard Features Power Factor Corrected...

Страница 15: ...mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The follo...

Страница 16: ...process any unit returned to the factory In consulting the factory always have the unit model number and serial number at hand This information is located on the identification label and is essential...

Страница 17: ...ssued Return Material Authorization RMA by calling 800 442 CLARY All transportation charges prepaid clearly tagged stating the nature of trouble experienced and the disposition of the equipment after...

Отзывы: