background image

 

 

T H E   C O N T I N U O U S   P O W E R   C O M P A N Y

 

Page 13 

SIGNALS AND INTERFACING 

t the rear of the unit are two DB-9 
subminiature, female connectors.  These are 
provided for communications links to a 
computer or sophisticated monitoring device. 

SIGNAL provides open-collector outputs that 
typically signal 

Utility

 

Interrupt

 and 

Low

 

Battery

 

conditions.  A system shutdown feature is also 
available on this port.  Applying a short between Pin 
6 and Pin 7 will cause the system to shutdown in 
battery mode.  This conserves the battery life once 

an orderly shutdown has been accomplished.  The 
system may be configured to shutdown by applying 
a +5 to +12V signal across the appropriate pins.  
Contact the factory for configuration details. 
RS232 is a true computer communications signal 
port. 
The open-collector signal outputs can be converted 
to dry contact closures, as an option.  Below is the 
pin out of the two connectors with their default 
assignments: 

OPEN-COLLECTOR CONNECTOR (SIGNAL) 

2- 

UTILITY INTERRUPTED SIGNAL 

4- 

COMMON SIGNAL RETURN 

5- 

LOW BATTERY SIGNAL 

6- 

+ UPS SHUTDOWN 

7- 

- UPS SHUTDOWN 

RS232 CONNECTOR 

2- 

TRANSMITTING DATA (TX) 

3- 

RECEIVING DATA (RX) 

6 & 8-  DATA SET READY 

5- SIGNAL 

GROUND 

 

DB-9F

 

SYSTEM 
SHUTDOWN 

-

+

 

LOW BATTERY 

UTILITY INTERRUPTED 

SIGNAL: OPEN-COLLECTOR CONTACT 

CONNECTOR

 

DB-9F

 

SYSTEM 
SHUTDOWN 

-

+

LOW BATTERY 

UTILITY INTERRUPTED 

SIGNAL: DRY CONTACT CLOSURE (OPTION) 

CONNECTOR

 

RS232 CONNECTOR

 

GND

 

5

 

3

TX

 

RX

 

2

6

 

8

DB-9F

 

1K

+5V

DSR

Содержание S1500-601

Страница 1: ...ion is proprietary confidential and not to be disclosed disseminated or used except for the purpose provided by CLARY CORPORATION P N 510 14825 REV A PENDING 10 2006 CLARY SCIENTIFIC INC 150 E Hunting...

Страница 2: ...TS TITLE PAGE TABLE OF CONTENTS 2 INTRODUCTION 3 TECHNICAL DESCRIPTION 4 PACKAGING 6 PHYSICAL DESCRIPTION 7 SUMMARY OF INDICATORS AND CONTROLS 10 INSTALLATION 11 OPERATION 12 SIGNALS AND INTERFACING 1...

Страница 3: ...in accordance with the directions presented Any and all equipment modifications must be authorized in writing by Clary Corporation and executed by appropriately assigned qualified personnel The electr...

Страница 4: ...are available The microprocessor controls an Inverter Generator that produces a low harmonic AC sinewave for continuous power applications When the input AC utility line fails the battery circuit wit...

Страница 5: ...UTILITY INPUT INPUT ISOLATION TRANSFORMER BYPASS LINE EMERGENCY CUTOFF SWITCH VOLTAGE WINDOW DETECTOR COMMON MODE CHOKE RECTIFIER CHARGER POWER FACTOR CORRECTOR DC RAILS MICROPROCESSOR CONTROLLER AC I...

Страница 6: ...cking material for future use Take extra precaution when removing or returning it to the box Because this unit contains a battery it can be quite heavy Never attempt to unpack the equipment unassisted...

Страница 7: ...t the bottom with a brief identification In the next section a complete explanation of all numbered items will be enhanced to ensure you have a full understanding of the operation of this system Visua...

Страница 8: ...tery Level Charge discharge indicators 11 LOAD II ACKNOWLEDGE INDICATOR 5 Load Level Output capacity indicators 12 Alarm Silent Test Dual function switch 6 Cold Start DC start switch 13 ALARM SILENT T...

Страница 9: ...ut line protection 20A 250V 20 RS232 Computer communications signals 17 DC INPUT Auxiliary battery connector for 72VDC system 21 IDENTIFICATION LABEL 18 120VAC OUTPUT System output 22 SNMP Optional Sl...

Страница 10: ...minals at the rear panel SNMP Optional A slot available to install an interface card to provide system network management Alarm Silent Test A momentary push button switch that controls two different f...

Страница 11: ...em remains cooler during operation there is less stress on the batteries and the internal electronics The air inlets vents and fan should not be obstructed or blocked in any way The more breathing spa...

Страница 12: ...Mode DC Start Operation Cold Start If no utility power is available at the time backup power is required the unit may be started to accomplish abbreviated tasks The limitations of the battery prevent...

Страница 13: ...own by applying a 5 to 12V signal across the appropriate pins Contact the factory for configuration details RS232 is a true computer communications signal port The open collector signal outputs can be...

Страница 14: ...y 1 Duplex 5 15R Cooling Low Velocity Temperature Controlled Reversible Forced Air Dimensions HxWxD in cm 14 1 36 x 6 9 17 5 x 21 53 Weight lbs kg 80 36 DESIGN Standard Features Power Factor Corrected...

Страница 15: ...mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The follo...

Страница 16: ...process any unit returned to the factory In consulting the factory always have the unit model number and serial number at hand This information is located on the identification label and is essential...

Страница 17: ...ssued Return Material Authorization RMA by calling 800 442 CLARY All transportation charges prepaid clearly tagged stating the nature of trouble experienced and the disposition of the equipment after...

Отзывы: