8
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
BEFORE USE
CONNECTING THE AIRLINE
1. Remove the travel plug.
2. Pour 2-3 drops of CLARKE airline oil
into the oil filling port. This should
be done regardless of whether or
not a lubricated air supply is used.
3. If required, connect an in-line mini
oiler to the tool. Read the
instructions supplied with the mini-
oiler before use.
• A mini oiler helps to prolong the
life of any air tool.
4. Connect a suitable hose. This can
be done using either the male
adaptor supplied or using a mini
oiler from your CLARKE dealer.
5. Connect the other end of the hose
to the compressor.
• PTFE tape may be useful for
sealing threaded connections.
6. Turn on the air supply and check
for air leaks. Rectify any found
before proceeding. Set the working pressure to 90psi (6.2 bar) for best
performance
7. Place a sheet of paper next the exhaust port and squeeze the trigger for
approximately 30 seconds. The oil volume is correctly set when a light stain
of oil can be seen on the paper. Excessive oil should be avoided.
WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR
COMPRESSORS AND A COMPRESSED AIR SUPPLY.
Содержание X-Pro CAT200
Страница 16: ......