TROUBLESHOOTING
STORAGE
When not in use, disconnect from the air supply, clean & store in a safe, dry
place. If the tool is to be stored, or is idle for longer than 24 hours, run a few
drops of CLARKE air line oil into the air inlet, and run the tool for 5 seconds in
order to lubricate the internal parts.
When storing, replace the blanking plug on the airline inlet once the airline has
been disconnected.
SYMPTOM
PROBLEM
SOLUTION
Tool runs at normal
speed but slows down
under any load.
1. Motor parts worn.
2. Worn or sticking
mechanism due to
lack of lubricant.
1. Return to CLARKE dealer
for repair.
2. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
Tool runs slowly. Air flows
weakly from exhaust.
1. Motor parts jammed
with gum/dirt.
2. Air-line regulator in
closed position.
3. General airflow
blocked by dirt.
1. Examine inlet air filter for
blockage and clean if
necessary. Drip a few
drops of air tool lubricat-
ing oil into air inlet.
2. Adjust in-line regulator to
open position.
3. Operate tool in short
bursts.
Tool will not run. Air flows
freely from exhaust.
1. Motor vanes stuck
due to buildup of
foreign material.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.
Tool will not shut off.
1. O-rings damaged
or ill-fitting in seat.
1. Return to CLARKE dealer
for repair.
Содержание X-Pro CAT200