TROUBLE SHOOTING

 A. PUMP WILL NOT START

1. Check to ensure Power is switched on.

2. Check fuse (consult an electrician if in doubt).

3. If extension lead is fitted, check connections (consult an electrician if in

doubt).

4. Internal thermal cutout has not reset. Leave for 15 minutes and try again.

5. The Impeller may be jammed. Disconnect from the mains supply, remove

the bottom strainer and outlet connection. Remove any objects that may
be obstructing the impeller. Replace the strainer and try again.

6. Float switch may be jammed against side wall or prevented from moving.

7. Water level too low  - float switch in OFF position - Lift float to check switch.

If the pump still fails to start, consult your CLARKE dealer for advice.

 B. PUMP WILL START BUT NOT PUMP

1. Check to ensure strainer is not blocked - clean as necessary

2. Discharge tube clogged or obstructed - clear as necessary.

3. The head may be too great, i.e. you are trying to lift the water too great a

distance for the pump to cope with. (See specifications pages 10 ).

4. Impeller may be damaged - Consult your CLARKE dealer

 C. PUMP WILL NOT STOP

1. Float switch may be prevented from moving to the fully down position.

2. Float switch may be faulty. Consult your CLARKE dealer for advice.

 D. PUMP STOPS RUNNING

1. Thermal overload has operated. If this condition persists, investigate the

cause. Are you attempting to pump liquid which is too dense for the pump
(mud, slurry etc.), or too high a temperature.

2. Pump has run dry, or float switch has cut in.

3. A foreign object has jammed the impeller.

9

Содержание ISP10A

Страница 1: ...Model ISP10A SUBMERSIBLE WATER PUMP 1203 SUBMERSIBLE WATER PUMP Model ISP10A OPERATING MAINTENANCE INSTRUCTIONS...

Страница 2: ...s for your own safety and for that of others around you and will also help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faults in manufacture f...

Страница 3: ...be removed from the water and stored in a frost free location 10 If the pump is to be used where there may be silt or mud e g garden ponds ALWAYS keep the pump clear of any sediment by standing it on...

Страница 4: ...f this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol o...

Страница 5: ...d of all contaminants The maximum depth to which the pump should be submerged is 5 metres and it will deliver water to a max head of 6 5 metres The pump is fitted with a Float Switch and is suitable f...

Страница 6: ...lar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached t...

Страница 7: ...Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restart Do not attempt to repair the pump yourself as...

Страница 8: ...fails to start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessa...

Страница 9: ...pacity 350 l min Max Water Temperature 50 C Gross Weight 11kg Cable Length 10M Dimensions Ref fig 3 A 196mm C 180mm H 361mm H1 88mm Part No 7230090 Fig 2 WARNING Connection to the mains supply MUST be...

Отзывы: