INSTALLATION

The pumps’ delivery outlet is provided with a 2” BSP  female thread, for connection
to a suitable adapter (not provided). It is advisable to seal the thread with PTFE, or
similar tape, to ensure maximum performance from your pump.

The delivery hose used should be of the same ID as the delivery outlet and
completely sound. Any holes, no matter how small, will reduce the efficiency of
the pump, or even prevent the pump from delivering water at all. Smaller diameter
hose will  reduce capacity and put additional strain on the motor.

Where it is necessary for long horizontal stretches of delivery hose to be used, the
hose ID should be greater than that of the delivery outlet.

Having connected the delivery hose, secure a  suitable length of rope or chain to
the pump handle, and plunge the pump into the water.

The pump must be in a vertical position on a  solid flat surface. If this is not available,
sit the pump on house bricks, or something similar, and ensure that this type of
support is not likely to shift.

The pump should be well clear of silt, mud or any type of marine growth.

IMPORTANT

:

ALWAYS 

raise and lower the pump using a rope attached to the lifting

handle, 

NEVER 

by the power cable.

7

Ensure the sump, or bore hole, has
adequate dimensions so as not to restrict
the movement of the float switch (see
fig.1 for recommended minimum size).

The calculation, for the dimensions of the
bore hole, must also take into account
the quantity of water arriving and the
pump flow rate, so as not to subject the
motor to excessive starting operations,
bearing in mind, 

the pump should not be

started more than 20 times per hour.

Take all necessary precautions as
described on page 4  before plugging
in, and switching ON.

NOTE:
a.

The symbol          on the pumps’ Rating Plate, denotes the MAXIMUM depth to
which the pump may be submerged, in metres.

b.

When the pump is used in a permanent or semi-permanent installation, a
check valve MUST be fitted in the  delivery pipe.

IMPORTANT:In such situations, care must be taken to ensure that all air is
expelled from the delivery side of the pump when immersing in water.

Fig.1

Содержание ISP10A

Страница 1: ...Model ISP10A SUBMERSIBLE WATER PUMP 1203 SUBMERSIBLE WATER PUMP Model ISP10A OPERATING MAINTENANCE INSTRUCTIONS...

Страница 2: ...s for your own safety and for that of others around you and will also help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faults in manufacture f...

Страница 3: ...be removed from the water and stored in a frost free location 10 If the pump is to be used where there may be silt or mud e g garden ponds ALWAYS keep the pump clear of any sediment by standing it on...

Страница 4: ...f this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol o...

Страница 5: ...d of all contaminants The maximum depth to which the pump should be submerged is 5 metres and it will deliver water to a max head of 6 5 metres The pump is fitted with a Float Switch and is suitable f...

Страница 6: ...lar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached t...

Страница 7: ...Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restart Do not attempt to repair the pump yourself as...

Страница 8: ...fails to start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessa...

Страница 9: ...pacity 350 l min Max Water Temperature 50 C Gross Weight 11kg Cable Length 10M Dimensions Ref fig 3 A 196mm C 180mm H 361mm H1 88mm Part No 7230090 Fig 2 WARNING Connection to the mains supply MUST be...