Clarke ISP10A Скачать руководство пользователя страница 4

5

ELECTRICAL CONNECTIONS

The mains lead should be connected to a standard 230Volt (50Hz) electrical supply
through an approved 13Amp BS 1363 plug or a suitably fused isolator switch. We
recommend that the pump be connected via a Residual Current Device (RCD).

I

MPORTANT:

If used for draining swimming pools or ponds, it is mandatory that the

pump be fitted with a Residual Current Device (RCD), with a rated

residual operating current of no greater 30mA.

If the pump is to be connected to an outdoor electrical supply, make sure that
both the plug and the socket are of a BS approved waterproof design.

In the event that the pump is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT:

 The wires in the mains lead are coloured in accordance with the

following code:

Green & Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:

Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or
Earth symbol “     ” or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter “L” or coloured RED

Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK

FUSE RATING

The fuse in the plug for this appliance must be rated at 

13 amps

.

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most
electrical outlets

5.

The fuse in the plug must be replaced with one of the same rating (

13 amps

)

and this replacement must be approved to BS1362.

Содержание ISP10A

Страница 1: ...Model ISP10A SUBMERSIBLE WATER PUMP 1203 SUBMERSIBLE WATER PUMP Model ISP10A OPERATING MAINTENANCE INSTRUCTIONS...

Страница 2: ...s for your own safety and for that of others around you and will also help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faults in manufacture f...

Страница 3: ...be removed from the water and stored in a frost free location 10 If the pump is to be used where there may be silt or mud e g garden ponds ALWAYS keep the pump clear of any sediment by standing it on...

Страница 4: ...f this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol o...

Страница 5: ...d of all contaminants The maximum depth to which the pump should be submerged is 5 metres and it will deliver water to a max head of 6 5 metres The pump is fitted with a Float Switch and is suitable f...

Страница 6: ...lar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached t...

Страница 7: ...Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restart Do not attempt to repair the pump yourself as...

Страница 8: ...fails to start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessa...

Страница 9: ...pacity 350 l min Max Water Temperature 50 C Gross Weight 11kg Cable Length 10M Dimensions Ref fig 3 A 196mm C 180mm H 361mm H1 88mm Part No 7230090 Fig 2 WARNING Connection to the mains supply MUST be...