Clarke ISP10A Скачать руководство пользователя страница 7

8

MAINTENANCE

WARNING

Before checking the condition of the pump, ensure it is unplugged from the

mains supply. If the unit is hard wired, ensure the circuit breaker is open.

The pump should require no maintenance other than regular cleaning. Its’
mechanical seal is lubricated in an oil chamber, and its’ bearings are ‘sealed for
life’. If the pump starts to show signs of wear or damage, contact your CLARKE
dealer for advice. Do not use the pump if there is any damage to the mains
supply cable, or to the float switch or its cable.

Check the pump installation regularly to ensure  the base inlet is clear of leaves or
other debris.

Note that the pump is fitted with automatic thermal overload protection. If it
overheats due to an obstruction in the pump, or pumping warm water in excess
of 50

o

C for example, it will shut off automatically.  Switch the pump OFF and

disconnect from the mains supply. Check for blockages and allow the motor to
cool (at least 15 minutes) before attempting to restart.

Do not attempt to repair the pump yourself, as you may damage the seals and
invalidate your guarantee.  Repairs must be carried out by a qualified pump
engineer, your CLARKE dealer, or contact the CLARKE Service Department, on:

 020 8988 7400

If the pump becomes badly clogged, backflush the pump chamber by directing
a jet of clean water through the outlet port.  If you remove the outlet port adapter
when you perform this operation, take the opportunity to inspect the impeller for
wear or damage, viewing it through the outlet port.

WARNING:

Do not attempt to strip the pump further as this will invalidate the guarantee

ANNUALLY OR EVERY 2000 WORKING HOURS

 (Whichever is sooner)

The sealing oil must be checked by a qualified pump engineer. Consult your Clarke
dealer, or Clarke International Service Department.

SUITABLE HOSE AND HOSE ADAPTERS

ARE AVAILABLE FROM YOUR CLARKE DEALER

Содержание ISP10A

Страница 1: ...Model ISP10A SUBMERSIBLE WATER PUMP 1203 SUBMERSIBLE WATER PUMP Model ISP10A OPERATING MAINTENANCE INSTRUCTIONS...

Страница 2: ...s for your own safety and for that of others around you and will also help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faults in manufacture f...

Страница 3: ...be removed from the water and stored in a frost free location 10 If the pump is to be used where there may be silt or mud e g garden ponds ALWAYS keep the pump clear of any sediment by standing it on...

Страница 4: ...f this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol o...

Страница 5: ...d of all contaminants The maximum depth to which the pump should be submerged is 5 metres and it will deliver water to a max head of 6 5 metres The pump is fitted with a Float Switch and is suitable f...

Страница 6: ...lar and ensure that this type of support is not likely to shift The pump should be well clear of silt mud or any type of marine growth IMPORTANT ALWAYS raise and lower the pump using a rope attached t...

Страница 7: ...Switch the pump OFF and disconnect from the mains supply Check for blockages and allow the motor to cool at least 15 minutes before attempting to restart Do not attempt to repair the pump yourself as...

Страница 8: ...fails to start consult your CLARKE dealer for advice B PUMP WILL START BUT NOT PUMP 1 Check to ensure strainer is not blocked clean as necessary 2 Discharge tube clogged or obstructed clear as necessa...

Страница 9: ...pacity 350 l min Max Water Temperature 50 C Gross Weight 11kg Cable Length 10M Dimensions Ref fig 3 A 196mm C 180mm H 361mm H1 88mm Part No 7230090 Fig 2 WARNING Connection to the mains supply MUST be...

Отзывы: