![Clarke IBC25 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/clarke/ibc25/ibc25_operation-and-maintenance-instructions-manual_2614500005.webp)
5
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
THE CHARGING PROCESS
STEP 1: DIAGNOSIS
Check if the battery has connected with the charger and also check the
battery voltage.
STEP 2: DESULPHATION
If battery voltage is too low, the program automatically generates a pulsing
current to remove sulphate.
STEP 3: ANALYSE
Check if the battery voltage reaches to the minimum threshold after
desulphation, and charging begins if the battery voltage is OK.
STEP 4: SOFT START
Charge with stepped constant current.
STEP 5: BULK
Charge with constant maximum current until the battery voltage has reached
the threshold.
STEP 6: ABSORPTION
Provide gradually declining current charge for maximum battery voltage.
STEP 7: ANALYSE
Test if the battery can hold charge
STEP 8: MAINTENANCE
Continuously monitor the battery, and charging current will intelligently adapt
to the variable battery voltage. (pulse form protection)
Содержание IBC25