TRIO SCRUBBER DIAGNOSTIC CODES CON’T.
7601
7602
7603
7604
7700
7701
7702
7703
7800
7801
7802
7900
7901
Soft brush current
foldback
Soft brush current
foldback 2
Soft brush current
foldback 3
Brush inhibit active
Soft vacuum motor
disconnected error
Soft vacuum current
foldback
Soft vacuum current
foldback 2
Soft vacuum current
foldback 3
Motor fault 1
Traction over current
error
Traction motor in
foldback state
Emergency stop
error
Belly button switch
activated
Brush current overload
Incorrect programming, incorrectly specified
(“thermal” trip).
brush motor, brush motor developing fault,
excessive resistance on brushes or brushes
pushing down too hard on floor.
Brush current overload
Incorrectly specified brush motor; brush motor
(“magnetic” trip).
developing fault.
Possible short circuit on brush
Check brush motor connection on Trio, check
motors or wiring.
wiring from this connection all the way down to
brush motor. Otherwise, possible brush motor
fault.
Dependent on programming.
Incorrect software program-check program.
Otherwise, possible controller fault.
Open circuit on vac motors or
Check vac motor connection at Trio; check this
vac motor wiring.
conection down to vac motor & all wiring in
between. Otherwise, possible vac motor fault.
Vacuum current overload
Incorrect programming; incorrectly specified vac
(“thermal” trip).
motor; vac motor developing fault; debris in vac
motor or airways blocked by debris.
Vacuum current overload
Incorrect programming; incorrectly specified vac
(“magnetic” trip).
motor; vac motor developing fault.
Possible short circuit on vac
Check vac motor connection at Trio; check this
motor or vac motor wiring
conection down to vac motor & all wiring in
between. Otherwise, possible vac motor fault.
Open circuit on traction motor or
Check traction motor connection on Trio; check
traction motor wiring.
wiring from this connector down to traction
motor & all connections in between. Otherwise,
possible traction motor fault.
Possible short circuit on traction
Check traction motor connection on Trio; check
motor or wiring.
wiring from this connector down to traction
motor & all connections in between. Otherwise,
possible traction motor fault.
Traction motor current has
Excessive driving up incline or machine has
exceeded limit for foldback time.
been up against an obstacle or step.
E-stop input active or wiring fault.
Check for wiring short circuits on Trio’s 20-way
connector, the LCD’s 16-way connector (if used)
& the wiring to emergency stop switch & switch
itself. Otherwise, incorrect operation of machine.
E-stop input active or wiring fault
Check for wiring short circuits on Trio’s 20-way
(programmed as belly button).
connector, the LCD’s 16-way connector (if used)
& the wiring to emergency stop switch & switch
itself. Otherwise, incorrect operation of machine.
Содержание ENCORE MAX
Страница 2: ...1 2 CLARKE ENCORE MAX NOTES...
Страница 16: ...1 16 CLARKE ENCORE MAX SPECIFICATIONS...
Страница 53: ...CLARKE 1 53 ENCORE MAX ELECTRICAL SCHEMATIC PG 53 REMOVE INSERT 11 X 17...
Страница 54: ...1 54 CLARKE ENCORE MAX WIRE HARNESS CONNECTIONS PG 54 REMOVE INSERT 11 X 17...
Страница 55: ...CLARKE 1 55 ENCORE MAX NOTES...
Страница 57: ...CLARKE 1 57 ENCORE MAX WIRE HARNESS ROUTING PG 57 Ref 71716 3 REMOVE INSERT 11 X 17...
Страница 58: ...1 58 CLARKE ENCORE MAX 11 x 17 WIRE HARNESS CONNECTIONS SPRAY WAND PG 58...