CLARKE
1-59
ENCORE MAX
CODE PGDT TECHNICAL PROBABLE CAUSE SERVICE ACTION
DESCRIPTION
0003
0100
0204
0705
0706
0810
0811
0812
0813
0814
0815
0816
0817
0818
0A01
0B0B
1310
1500
1501
1507
1600
1704
1705
1706
1800
1802
1B20
1B21
1D02
1E03
1E04
2102
2103
2C00
2C01
EEPROM program
checksom error 2
Running checksom 1
EEPROM program
checksum error 1
2.5V reference error
High switch
reference error
Tiller fault 1
Tiller maximum
wiper difference
error
Tiller maximum pull-
down difference error
Tiller maximum pull-
safe difference error
Tiller reference error
Tiller lo reference
error
Tiller hi reference
ISO error
Tiller lo reference
ISO error
Tiller error both have
readings
Power down error
EEPROM Q Overflow
Excessive current trip
Brake fault 1
Brake fault 2
Brake overcurrent
error
High battery voltage
Relay monitor failure
Relay fault 1
Relay fault 2
Watchdog error
Watchdog voltage
reference error
Both clamps
measuring current
Traction phase
overflow error
Front end spec
change
Inhibit activated
Inhibit activated 2
Progress counter
error
Progress counter
error 2
Low battery error
Low battery error 2
Memory corrupt.
Replace controller if not cleared by
disconnecting batteries for 1 minute.
All 070x codes - Wiring short
Check for wiring short circuits on the Trio’s
circuit between Tiller Hi & Lo
20-way connector, the LCD’s 16-way connector
Ref.
(if used) & the wiring to front panel switches &
controls, and the actual switches & controls.
All 081x codes - Throttle wiring
Check wiring for short circuits or broken wires on
short or open circuits.
Trio’s 20-way connector, the LCD’s 5-way
connector (if used) & the wiring to front panel
0816 & 0817 can be caused by
speed/throttle control, and the actual control.
incorrect programming of the ISO
test parameter.
Controller fault.
Replace controller if not cleared by disconnecting
batteries for 1 minute.
Check the Trio’s traction motor connection, check
wiring from this connector down to the traction
All 150x codes - Check brake &
motor, checking all connections along the way.
wiring for open or short circuit.
Otherwise, possible fault in traction motor’s
electro brake or possible controller fault.
Voltage exceeds maximum.
Check for poor or corroded battery connections.
Can also be caused by charger being connected.
Possible controller fault.
Replace controller if not cleared by disconnecting
batteries for 1 minute.
Tiller settings updated in program Cycle the power by using the key switch.
Inhibit inputs - exact usage
Remove or correct the cause of inhibit.
dependent on programming.
Otherwise, check all wiring, including Trio 20-way
connector for short circuits & breaks. Can also
be incorrect machine programming/operation.
Possible controller fault.
Replace controller if not cleared by disconnecting
batteries for 1 minute.
Low voltage warning.
Recharge batteries immediately.
TRIO SCRUBBER DIAGNOSTIC CODES
Содержание ENCORE MAX
Страница 2: ...1 2 CLARKE ENCORE MAX NOTES...
Страница 16: ...1 16 CLARKE ENCORE MAX SPECIFICATIONS...
Страница 53: ...CLARKE 1 53 ENCORE MAX ELECTRICAL SCHEMATIC PG 53 REMOVE INSERT 11 X 17...
Страница 54: ...1 54 CLARKE ENCORE MAX WIRE HARNESS CONNECTIONS PG 54 REMOVE INSERT 11 X 17...
Страница 55: ...CLARKE 1 55 ENCORE MAX NOTES...
Страница 57: ...CLARKE 1 57 ENCORE MAX WIRE HARNESS ROUTING PG 57 Ref 71716 3 REMOVE INSERT 11 X 17...
Страница 58: ...1 58 CLARKE ENCORE MAX 11 x 17 WIRE HARNESS CONNECTIONS SPRAY WAND PG 58...