
CLARKE
1-33
ENCORE MAX
SOLUTION
TANK
RECOVERY
TANK
SOLUTION
CONTROL
VALVE
SCRUB
BRUSH
SQUEEGEE
FLOOR
CONTACT
STRAINER
SOLUTION
PUMP
STRAINER
ESP OPERATING MODEESP OPERATING MODE
During the scrubbing process, filtered water from the solution tank is fed to the solution line and then to the
floor where two disc scrubbing brushes work to dislodge soil. After scrubbing, the dirty solution is vacuumed
from the floor and discharged into the recovery tank. At intervals, a float switch activates the recycling pump,
which sends filtered solution from the recovery tank to the solution tank.
OPERATING INSTRUCTIONS
Fig. 33
Содержание ENCORE MAX
Страница 2: ...1 2 CLARKE ENCORE MAX NOTES...
Страница 16: ...1 16 CLARKE ENCORE MAX SPECIFICATIONS...
Страница 53: ...CLARKE 1 53 ENCORE MAX ELECTRICAL SCHEMATIC PG 53 REMOVE INSERT 11 X 17...
Страница 54: ...1 54 CLARKE ENCORE MAX WIRE HARNESS CONNECTIONS PG 54 REMOVE INSERT 11 X 17...
Страница 55: ...CLARKE 1 55 ENCORE MAX NOTES...
Страница 57: ...CLARKE 1 57 ENCORE MAX WIRE HARNESS ROUTING PG 57 Ref 71716 3 REMOVE INSERT 11 X 17...
Страница 58: ...1 58 CLARKE ENCORE MAX 11 x 17 WIRE HARNESS CONNECTIONS SPRAY WAND PG 58...