WARNING:
Ensure the plug is removed from the socket before carrying out any
adjustment, servicing or maintenance.
AFTER EACH USE
When using chemical detergents, always ensure the system is thoroughly flushed
out after use as described above.
Ensure the hoses and power cable are coiled and properly stowed. DO NOT allow
them to be left casually, in a heap. This invites damage and will cause rapid
deterioration.
MAINTENANCE
STORAGE
S
tore the Washer in a vertical position,
preferably under cover, protected from
the elements.
If there is a danger of freezing, the pump
should be filled with antifreeze by inserting
the inlet and outlet hoses into a bucket of
antifreeze as shown in fig. 7.
Start the machine and allow the antifreeze
to circulate. After a short time stop the
machine using the procedure outlined on
page 9, and store the machine with the
antifreeze still within the pump body.
NOTE:
If you experience difficulty in starting the motor following a long period of storage, it is possible that
the seals within the pump have dried out and are gripping the pistons. This problem may be alleviated
by storing the machine with antifreeze within the pump body, as described above.
If the seals are stuck however, disconnect the machine from the electrical and water
supply’s, and proceed to free them as follows:
Fig.7
Remove the front cover by unscrewing the three
securing screws, one at the top, centre (A fig. 7),
and one at either side at the bottom (B, fig. 7), to
reveal the motor.
On the top of the motor is a circular plastic grill,
covering the motors’ fan. In its’ centre is a hole,
through which can be seen the head of a hex.
socket head screw.
Insert a hex. wrench (not supplied), through the
hole, into the screw head, as shown in fig.8, and
turn the motor a turn or two to free it. It should
now be possible to start in the normal way.
10
Fig.8
Содержание ELS140
Страница 14: ...15...