background image

4.

STARTING WORK:

Ensure the work area is as hazard free as
possible.

Select and install the tool to be
used,(see paragraph 

2

).

If required set the depth stop and adjust
the support handle attachment  for the
most comfortable position, (see fig.3). To
install the depth stop loosen the support
handle by turning it anticlockwise. Insert
the depth stop rod through the hole in the
support handle and set to the required
depth, adjust the position of the handle
attachment if required and secure in
place by re-tightening the support
handle.

For safety, always use the hammer drill
with the handle attached.

Set the required mode, (see paragraph 

5

).

When drilling vertically overhead, fit the rubber
dust collector onto the drill (see fig.4).

Position the tool against the surface to be drilled,
depress the OFF lock knob (10) and then squeeze
the trigger switch (3).

NOTE: if using the hammer action DO NOT start
the drill  until the tool is in contact with the
surface to be drilled/chiselled etc.

5.

DRILL MODE SELECTION

HAMMER STOP:

Your drill is equipped with a hammer stop facility for smoother drilling. To select

this mode turn the hammer control switch (7) to the position marked: 

 .

Depress the lock pin (9) then turn the drill control (8) so that the position marked:

  coincides with the arrow on the machines case.

Fig.3

SETUP AND OPERATION CONTINUED

Fig.4

- 8 -

Содержание CRD1250

Страница 1: ...USER INSTRUCTIONS Model No CRD1250 Part No 6482015 0306 SDS PLUS 1250W ROTARY HAMMER DRILL SDS PLUS 1250W ROTARY HAMMER DRILL ...

Страница 2: ...he safety of yourself and that of others around you this will also ensure that the SDS Plus 1250W Rotary Hammer Drill will give you long and satisfactory service Please keep these instructions in a safe place for future reference CLARKE GUARANTEE Guarantee 1 General Safety Precautions 2 Additional Safety Precautions 3 Electrical Connections 4 Technical Specification 5 Package Contents 6 General Vi...

Страница 3: ...tool machine from the power supply before servicing and when changing accessories ALWAYS wear safety goggles manufactured to the latest European safety standards Everyday glasses do not have impact resistant lenses they are NOT safety glasses ALWAYS wear ear protectors to protect your hearing ALWAYS keep work area clean cluttered areas and benches invite accidents ALWAYS ensure that adequate light...

Страница 4: ...shock use a suitable RCD residual current device GENERAL SAFETY PRECAUTIONS CONTINUED ADDITIONAL PRECAUTIONS FOR POWERTOOLS ALWAYS check that the chisel or drill bit is properly locked into the chuck BEFORE starting work and that it is appropriate for the material being cut ALWAYS secure all work sufficiently using a vice or clamps Do not use hands to secure work as this would be extremely dangero...

Страница 5: ...dicated by marker or colour code The fuse in the plug MUST be replaced with one of the same rating 13amps and this must be approved to BS1362 IMPORTANT If in any doubt do not attempt any electrical repair yourself Consult a qualified technician IMPORTANT Always use an approved cable extension suitable for the power rating of this tool see specifications the conductor size should also be at least t...

Страница 6: ...ct use classification Light Industrial Noise Emissions Sound Power Measured Hammer Drill 87 0 dB LWA Hammer Only 98 0 dB LWA Sound Power Guaranteed Hammer Drill 98 0 dB LWA Hammer Only 106 0 dB LWA Vibration Emissions Measured Emission RMS a m s 3 5m s refer to page 12 for hand arm vibration explanation Motor Operating voltage and frequency 230V 50Hz Input Wattage 230V Typical load 1250W Input Amp...

Страница 7: ...le x1 4 Drill chuck 1 3mm 13mm x1 5 Chuck key x1 6 Dust cap x1 7 Spare set of brushes x1 8 Pot of grease x1 9 Black moulded bit case x1 10 8mm SDS plus masonry drill bit x1 11 10mm SDS plus masonry drill bit x1 12 12mm SDS plus masonry drill bit x1 13 SDS plus masonry chisel bits x2 14 Depth rod x1 15 Wrench x1 16 Operators manual not shown x1 6 ...

Страница 8: ...stening sleeve the tool will then be locked in automatically Check the tool is locked in securely by attempting to pull the tool out 3 REMOVING TOOLS Ensure the drill has completely stopped and is disconnected from the electrical supply Pull back the fastening sleeve and hold pull the tool out of the tool holder and store safely NOTE for your protection if the tool is hot either allow it to cool d...

Страница 9: ...drill with the handle attached Set the required mode see paragraph 5 When drilling vertically overhead fit the rubber dust collector onto the drill see fig 4 Position the tool against the surface to be drilled depress the OFF lock knob 10 and then squeeze the trigger switch 3 NOTE if using the hammer action DO NOT start the drill until the tool is in contact with the surface to be drilled chiselle...

Страница 10: ...ug from the 13 amp socket before commencing any maintenance activities or adjustments etc Clean the tool regularly use a soft brush and or soft cleaning cloth DO NOT use any chemicals or harsh abrasives to clean the tool At the end of work to prevent dust deposits you should use a compressed air max 3 bar to clean out the ventilation holes Remove and inspect the carbon brushes regularly it is very...

Страница 11: ...PARTS DIAGRAM 10 ...

Страница 12: ...8 49 Motor Housing TMC1250049 50 Bearing 608Z TMC1250050 51 Bearing Bush TMC1250051 PARTS LIST ITEM DESCRIPTION PART NO 52 Rear Cover TMC1250052 53 Tapping Screw TMC1250053 54 Capacitor TMC1250054 55 Switch TMC1250055 56 Bearing 627Z TMC1250056 57 Circlip TMC1250057 58 Washer TMC1250058 59 Steel Ball TMC1250059 60 Spring TMC1250060 61 Second Gear TMC1250061 62 Wheel Core TMC1250062 63 Circlip TMC1...

Страница 13: ...es appear in the declaration on page 7 HAND ARM VIBRATION You will note that a third value is given in the specification the highest measured reading in a single plane This is the maximum level of vibration measured during testing in one of the axes and this should also be taken into account when making a risk assessment a values in excess of 2 5 m s2 are considered hazardous when used for prolong...

Страница 14: ... 13 ...

Отзывы: