Troubleshooting
Problem
Cause
Action
Motor will not start.
No power.
GFCI tripped.
Interlock not depressed.
Defective switch/ Bad connection
Check power supply and connection
Reset GFCI.
Depress Interlock before activating control
lever.
Contact an authorized Clarke
Dealer.
Motor fails to start / runs
sluggish.
Low voltage from excessive length
or undersized extension cord.
Defective start capacitor.
Defective start switch.
Defective start/run capacitor
Defective motor low voltage
Use a 14 Ga extension cord, not to exceed
50’ length.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.
Fuse / Circuit Breaker repeatedly
trips.
Low voltage.
Bad connection.
Defective motor.
Eliminate extension cord.
Locate power source closer to
work site. Have voltage checked by
a quali
fi
ed electrician.
Contact an authorized Clarke
Dealer.
Contact an authorized Clarke
Dealer.