SET-UP AND OPERATION
SET THE WORKING MODE
In automatic mode the AUTO light will be on. Press the SET button for 4 seconds
and the AUTO light will go off and the unit will be in normal mode.
Press the SET button for 4 seconds and the unit will return to AUTO mode.
SET THE STARTING PRESSURE
In AUTO mode, the controller will set a starting pressure according to the
pipeline pressure.
In RUN mode press the “+” or “-” button to enter the starting pressure setting.
The display will show L00. Press the SET button or wait 8 seconds to save and
exit the setting for normal operation.
• The controller has a memory function to store the chosen setting in
case of power outage.
To display the starting pressure, press RUN and SET at the same time.
If the display shows ”P- -”& blinks, it means the pump will restart in 30 minutes.
If the failure light blinks it means the pump will restart after 1 minute, 30 minutes
or 1 hour.
If the pump stops, press the RUN button to set it working again.
STARTING THE SYSTEM
1. Close all taps/valve on the discharge side of the pump.
2. After making sure that all precautions have been observed, ensure there is
power to the pump.
• The “Power” LED will light up and the “Pump” LED will indicate that
the pump has been started.
• The pump will continue to operate for a few seconds enabling the
system to fill and to reach the required pressure.
If this time is insufficient, the “FAILURE” LED lights up. If this happens, open a tap
and keep the “RUN” button pressed until the LED goes off, then release the
button and close the tap. The controller will stop the pump at its maximum
pressure.
CAUTION: ENSURE THE PUMP IS FULLY PRIMED BEFORE SWITCHING ON.
SEE YOUR PUMP INSTRUCTION MANUAL FOR DETAILS.