• Dry mode protection can re-start the pump if no flow after 48 hours
to discourage blockages.
• The digital display can be used to test and display starting pressure.
WORKING MODES
• In Automatic mode: the controller can automatically adjust the
starting pressure according to the pressure in the pipeline and can
monitor the pipeline pressure at any time. It does not need to be set
manually so avoiding a mismatch between the starting pressure and
the head of the pump, caused by the mismatch between the faulty
set starting pressure and the head of the pump.
• In Manual mode the starting pressure can be set between 0.5 and
6.0 bar.
SPECIFICATIONS
SAFETY PRECAUTIONS
1. DO NOT attempt to modify or alter the controller in any way.
2. Observe all electrical safety precautions. DO NOT allow the controller to be
submerged. Ensure it is protected from the elements at all times.
3. Read and comply with all precautions specified in your pump manual.
4. The controller should always be installed by a suitably qualified person who
is familiar with the appropriate electrical regulations.
Power supply
230V-50-60Hz
Maximum power
1.1 kw
Max. Ambient Water Temp.
60°C
Protection Rating
IP65
Maximum Operating Pressure
10 bar
Start-up pressure
0.5 - 6 bar
Water flow rate
120 L/min
Connection
G1" BSP external (male) thread.