CONNECTING THE PUMP TO THE CONTROLLER

WATER CONNECTION

The controller should be connected to a good quality water pump and a 
check valve should be fitted upstream of the pump. Confirm that the pump is 
operating before installing the controller.

The controller can be installed anywhere between the pump and the first tap.

No taps should be fitted between the pump and the controller.

Use a flexible hose to connect the controller to the delivery pipe and tap.

The controller can be connected directly adjacent to the pump and between 
the pump and the first outlet tap.

The controller must be installed in an upright position as shown by the direction 
arrows on the label. 

The vertical distance between the highest taps and the controller outlet being 
no more than shown in the table below.

ELECTRICAL CONNECTIONS

The EPC1200 controller is fitted with two cables.

1. One is fitted with a standard 13 amp plug.

• When connected to the mains supply, this cable carries the supply 

to both the controller and the pump.

2. The other cable should be fitted to a connecting socket for the pump.

3. If the controller is to be connected to an outdoor electrical supply, make 

sure that both the plug and the socket are of a BS approved waterproof 
design and are protected from the elements.

Starting 

Pressure (bar)

Distance of controller 

and highest tap max 

distance (m)

Theoretical value 

of the pump min 

head (m)

Suggested value 

of the pump min 

head (m)

1.2

12

13

17

1.5

15

16

20

2.2

22

23

27

Содержание 7230699

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC06 22 ELECTRONIC PUMP CONTROLLER MODEL NO EPC1200 PART NO 7230699...

Страница 2: ...pumps by instantly sensing water usage and automatically starting or stopping the pump 2 It protects the pump from running dry The EPC1200 controller has a built in safety circuit which switches the...

Страница 3: ...he faulty set starting pressure and the head of the pump In Manual mode the starting pressure can be set between 0 5 and 6 0 bar SPECIFICATIONS SAFETY PRECAUTIONS 1 DO NOT attempt to modify or alter t...

Страница 4: ...r must be installed in an upright position as shown by the direction arrows on the label The vertical distance between the highest taps and the controller outlet being no more than shown in the table...

Страница 5: ...7400 E mail Parts clarkeinternational com or Service clarkeinternational com MECHANICAL INSTALLATION You should always fit a non return valve to the suction line A foot valve and filter are available...

Страница 6: ...6 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING CONNECTIONS CONNECTING THE EPC1200 CONTROLLER TO DIFFERENT PUMPS...

Страница 7: ...is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recommend that this product is connected to the mains supply...

Страница 8: ...ight OFF pump will stop 3 AUTO 1 Light ON shows AUTO mode running no need to set starting pressure 2 Light OFF Normal Mode starting pressure set by the user 4 POWER Light ON System power supply normal...

Страница 9: ...e press RUN and SET at the same time If the display shows P blinks it means the pump will restart in 30 minutes If the failure light blinks it means the pump will restart after 1 minute 30 minutes or...

Страница 10: ...the problem 3 Switch on the controller at the mains and press the AUTO button The most common problems associated with water pump operation are leaks on the SUCTION side of the pump Even a pin hole in...

Страница 11: ...al PCB is broken Voltage is less than 200 v Pump jammed Cables incorrectly connected The pump does not stop Internal PCB is broken Check valve is stuck Water contains materials in suspension Pipeline...

Страница 12: ...of any surface mounted water pump or the delivery side of a submersible pump 25mm 1 diameter 90 threaded female hose adaptor An optional pump filter and cartridge for use with the various Clarke water...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATIONS OF CONFORMITY...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Страница 15: ...chase no product can be returned to us without prior permission This guarantee does not effect your statutory rights No Description No Description 1 Nameplate 20 Main housing 2 Screw 21 Check valve ba...

Страница 16: ......

Отзывы: