24
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
5. Remove the flange screw and outer flange.
6. Remove the blade from the inner flange.
7. Carefully clean the flange screw, outer flange and inner flange.
8. Fit a new saw blade in reverse order.
• Please note that spare blades are available from your CLARKE
dealer.
• Make sure that all parts are perfectly clean and the blade teeth
point down at the front.
• Every time that you change the saw blade, check to see that it spins
freely in the table insert in both perpendicular and 45° angle
settings.
9. Before continuing your work make sure that all safety devices are in good
working condition.
REPLACING THE TABLE INSERT
1. Remove screws at table insert. If
required, turn rotary table and
incline saw head to be able to
reach the screws.
2. Remove table insert.
3. Install new table insert.
4. Tighten the screws at table insert.
CHANGING THE CARBON BRUSHES
Check the carbon brushes after the first 50 operating hours with a new
machine, or when new brushes have been fitted. Then every 10 operating
hours.
1. Unscrew the carbon brush cover.
WARNING: IF THE TABLE INSERT IS DAMAGED THERE IS A RISK OF SMALL
PARTS GETTING STUCK BETWEEN TABLE INSERT AND SAW BLADE,
BLOCKING THE SAW BLADE. REPLACE DAMAGED TABLE INSERTS
IMMEDIATELY!
WARNING: MAKE SURE THAT THE SAW IS SWITCHED OFF AND UNPLUGGED
FROM THE MAINS SUPPLY BEFORE INSPECTING OR CHANGING THE