CONTROLS
BATTERY CHARGE INDICATORS:
1. Power
- A green LED illuminates to confirm power is being supplied to the
battery charger. If it is the only LED illuminated, the charger is in “Maintain
Mode”.
2.
Charged
- A green LED illuminates to signal that the battery is fully charged
and may be disconnected for use. It left “on charge”, the LED will turn off
after 1 hour and only the green power LED will stay illuminated.
3.
Charging
- An amber LED illuminated to signal that the charger is charging
the battery.
4.
Error
- A red LED illuminates if the connection is wrong, the incorrect battery
voltage is selected or the battery is faulty. In each of these instances, the
charging of the battery will not proceed.
NOTE:
The LCD will show Er1, if the clamps are “shorted”, loose or poorly
connected, if the battery voltage is less that 0.5V, or if the battery
voltage is >15.5V (for 12V Mode) or >7.8V (for 6V Mode).
NOTE:
The LCD will show Er2, if the battery is damaged or unable to be
charged.
NOTE:
The LCD will show Er4, if the clamps are connected incorrectly, i.e.
reverse polarity (+ve clamp to -ve battery terminal and -ve clamp to
+ve battery terminal).
NOTE:
Batteries with a battery voltage below 10.5V may be permanently
damaged. It is recommended that batteries not be discharged to
below 10.5V.