CHARGE CYCLES
S
TAGE
F
UNCTION
D
ESCRIPTION
1
Diagnosis
To determine whether the battery is defective.
Charging will not proceed if the battery voltage is
<0.5V and an error code will be displayed on the LCD.
2
Desulphation
This stage provides a stepped or pulsed voltage to
help remove the sulphation of plates which can occur
when the battery is left discharged for prolonged
periods. It also stabilises electrolytic balance and
minimises excessive battery temperature.
3
Pre-Charge
A low voltage and current is used to slowly increase
battery condition and further improve electrolytic
consistency which can become uneven due to day
to day use.
4
Soft Start
At an increased voltage, the current is slowly
increased over time to control heat, reduce gassing
and minimise battery stress.