Page 16 - MS3001 / MS3200 Installation Manual
The MS3001 / MS3200’s dual stage, on-board Shock Sensor is adjusted entirely through the use
of the Remote Transmitter.
Trigger Sensitivity
The Trigger sensitivity is adjustable to 8 levels, including an “off” setting where the sensor is
ignored.
To Adjust the Trigger sensitivity:
1. Turn the ignition key on.
2. Within 4 seconds, press Transmitter Button 1.
• The siren will chirp (1 through 8) to indicate the current sensitivity level. The default
shock sensitivity setting is 4.
3. Test the sensitivity. The siren will respond with a short chirp when shock is detected.
4. To make adjustments:
Press Button 1 to
increase the sensitivity.
Press Button 2 to
decrease the sensitivity.
• The siren will chirp to indicate the sensitivity level each time the Button is pressed.
• If the sensitivity is set to Level 1, the Shock Sensor is off.
5. When you are satisfied with the sensitivity, turn off the ignition.
When the sensitivity is set to Level 1, the siren will emit 1 chirp, followed by 3 chirps each time the system
is Armed to indicate that the Shock Sensor is off.
Warn Away Sensitivity
The sensitivity of the Shock Sensor’s Light Impact Response can also be adjusted. There are
two settings for Warn Away, High and Low. The default setting is High.
To Adjust the Warn-Away sensitivity:
1. Turn the ignition key on.
2. Within 4 seconds, press The Mode Button followed by Button 1. The siren will chirp to
indicate the setting:
One chirp
=
High
Two chirps
=
Low
3. Press Button 1 again to change the setting.
Note: To turn off the shock sensor for one arming cycle, use the “Remote Shock Sensor Bypass
(Dedicated Remote Start Mode)” feature available with the auxiliary function. See
Jumper
Settings.
Shock Sensor
Shock Sensor Sensitivity
Level
1 2
8
off lowest
highest