COMMISSIONING
regulations.
• Switch on the power supply to the appliance. The digital display
on the appliance must light up.
• When switching on the power supply for the first time, the
value “21“ (“12” for DEX12) flashes in the display. If not, please
carefully read the Re installation section of these instructions.
• Select the maximum allowable power rating depending on the
local situation via the up and down arrow keys.
Note: DEX set at 27 kW for connection only to 3/PE 400V AC
supply.
• Press key to confirm the setting. The appliance starts
operating.
• Mark the set power rating on the rating plate.
• Open the hot water tap. Check the function of the appliance.
• After having set the maximum allowable power rating, the heating
element will be activated after approx. 10 - 30 seconds of water
flow.
• Explain operation of the appliance to the end user and leave the
operating instructions for their reference.
• Complete the product registration card and return it to Zip or
register the product on line at
www.zipwater.co.uk/product-registration.
DEX
DEX 12
Reinstallation
Shower application
Fig. 13
The water heater’s temperature must be limited to 55 °C, if
it is connected to a shower. The service menu parameter
“Temperature Limit“ (“tL”) must be set to a value less or equal
55 °C (in consultation with the customer) and the lock level must
be activated.
When the device is operated with preheated water, it must be
ensured that this temperature is limited to 55 °C as well.
• If the appliance is to be recommissioned under different
installation conditions it may be necessary to alter the
maximum power rating.
• This should only be done by a competent installer.
• To re-set the maximum power rating use a screwdriver
(compliant to EN 60900, current issue) to short circuit the two
pins as shown in Fig. 13.
• This will reset all heater parameters to factory settings.
• Value “21” (“12” for DEX12) will flash in the display panel until
the maximum power rating has been selected.