26
M 3...7-O
EN
May only be carried out by a specialist.
Remove the cover, undo the hood screw underneath and remove the hood.
The maximum temperature and flow depend on the conditions at the installation site.
In case of quite low or high cold water temperatures, you may reduce or increase the flow with
the adjustment screw to achieve a comfortable outlet temperature. See figure below for direc-
tion of rotation:
–
+
+
–
Direction of rotation
Flow
Temperature
Fig. 11:
“Adjusting the water flow and temperature”
25
30
40
20
10
0
0,0
1,0
2,0
3,0
4,0
5,0
Temper
atur
e incr
ease [K]
Hot water output [l/min]
Fig. 12:
“Temperature increase and hot water output”
Use
3.2 Adjusting the water flow and temperature
MO-GMA-de-en-fr-nl-cs-sk-sv-pt-10-2018-BUCH-Offset.indb 26
12.10.2018 14:31:20