24
M 3...7-O
EN
M 3, M 4 (230 V)
M 6 (230 V)
M 7 (400 V)
Fig. 7:
“Circuit diagram”
Installation
Do not switch on the electric power at this time!
1. To purge the instantaneous water heater, open the hot water tap and wait until the water
emerges free of air bubbles.
2. In order to obtain an optimum water jet at low flow rates, screw the enclosed special tap
aerator into the tap outlet (M 22/24).
Fig. 8:
“Fitting the special tap aerator“
3. Switch on the electric power.
4. Adapt the water flow if necessary, if for example the temperature is not reached. The proce-
dure is described in the chapter “Use”.
5. Explain the functions and use of the instantaneous water heater to the user and hand over
these operating instructions to the user for information and future reference.
6. Register the appliance with the customer service department using the registration card or
online at www.clage.com.
2.6 Initial start-up
MO-GMA-de-en-fr-nl-cs-sk-sv-pt-10-2018-BUCH-Offset.indb 24
12.10.2018 14:31:18