7. Electrical Connection
7. Electrical Connection
P.14
P.15
Only by a specialist!
• VDE 0100
Please observe:
•
The installation must comply with current IEC and national local regulations or any particular
regulations, specified by the local electricity supply company
•
The rating plate and technical specifications
•
The unit must be earthed!
Structural prerequisites
•
The appliance must be installed via a permanent connection. Heater must be earthed! A cable size
of 10mm
2
must be observed.
• The electric wiring should not be injured. After mounting, the wiring must not be direct accessible.
• An all-pole disconnecting device (e.g. via fuses) with a contact opening width of at least 3 mm per
pole should be provided at the installation end.
•
To protect the appliance, a fuse element must be fitted with a tripping current commensurate with
the nominal current of the appliance.
Wiring diagram
1.Electronic circuitry
2.Heating element
3.Safety pressure cut-out
4.Terminal strip
5.Safety thermal cut-out
Electrical connection from below
Check that the power supply is switched off prior to
electrical connection!
1. Dismantle approximately 6 cm off the connecting
cable above the wall outlet. With the smaller
opening ahead, slide the water splash protection
sleeve over the connecting cable so that the sleeve
is flush with the wall. This prevents any leaking
water from coming into contact with the electrical
leads. It must not become damaged! The protection
sleeve must be used!
2. Open the control panel rightwards.
3. Strip the cables and plug them in the connecting
terminals according to the wiring diagram. The
appliance must be earthed.
4. Pull the protective sleeve over the connecting
cables until the sleeve fits perfectly in the recess
of the intermediate panel. Adjust the water splash
protection sleeve as illustrated. Reinsert the control
panel and lock it on the heating element.
5. Place the hood on the appliance and screw in the
fastening screw. After that you can reinsert the
faceplate.
Note
If necessary, the connecting terminal can be
displaced to the upper part of the appliance. If
you want to do so, please follow the instructions
in the next chapter.
180mm
60mm
8mm
Содержание German Pool DEX12
Страница 17: ...5 5 P 32 P 33 RDX 34100 VDX 34120 RDX UDX 34110 RDX RDX VDX UDX 1 12 12 2 6 3 30 2...
Страница 18: ...6 P 35 5 P 34 1 1 2 2 1 2 1 2 3 3 8 3 8 4 5 a 6 a 1 2 1 2 1 2 1 2 3 8 3 8 1 2 1 2 1 2...
Страница 19: ...7 7 P 36 P 37 VDE 0100 IEC 3 1 2 3 4 5 1 6 2 3 4 5 180mm 60mm 8mm...
Страница 20: ...8 P 39 7 P 38 1 S 2 3 6 4 5 6 7 8 9 1 DIN VDE0100 1 2 12 3 88 12 4 5 6 30 7 8 9 MPS 10 5kW 220V 8 0kW...
Страница 22: ...10 P 43 9 P 42 1 2 3 4 nr Ch rS 10 100 bL 0 1 2 tL IIC 1 2 3 a 4 b c 5 6 7 8 9 a c b...