Page 16
WS1.5", 2" and 2"QC Drawings and Service Manual
8) Drain Line Flow Control
Disassembly and Inspection
Depending on the
fl
ow control installed on the unit, remove the red plastic retaining clip (plastic
fl
ow control) or the (4) screws
(stainless steel
fl
ow control) to expose the
fl
ow control and retainer. The
fl
ow controls can be removed by
fl
exing the washer with
a small screwdriver being careful not to mar the plastic seat. The
fl
ow control and retainer may be chemically cleaned using dilute
sodium bisul
fi
te or vinegar, do not clean with abrasive methods.
Reassembly
Insert the
fl
ow washers back into their respective bores, con
fi
rming correct
fl
ow control orientation (see diagram in the exploded
view section). Place back into the housing and reassemble the housing /
fi
tting. Do not use Vasoline, oils or other unacceptable
lubricants on o-rings. A silicone lubricant may be used on the o-ring of the elbow or the retainer, but not on the
fl
ow control or its
seat.