No
Name
Function
1
Hook
Hook for hanging the product.
2
LCD
20 characters × 4 lines display.
3
Stop key
[STOP]
Use this key to stop the operation of the
actuator.
4
Operation keys
[UP]
Use these keys for various operations.
The LEDs light up when the operation keys can
be used.
[DOWN]
[LEFT]
[RIGHT]
[BACK]
[ENTER]
5
Connector
Connect to the controller.
Handy Terminal
ETP2
Compatible with the EC07, EC63, ECPT controllers
Specifications
Descriptions
ETP2
Display
20 characters × 4 lines (LCD)
Input keys
7 keys (Stop key: 1, Operation keys: 6)
Cable length
2 m
Supported controllers
EC07, EC63, ECPT
Supported actuators
ERL2/ESD2 Series
Operating ambient temperature
0 to 40°C (no freezing)
Operating ambient humidity
35 to 80% RH (no condensation)
Storage ambient temperature
-10 to 50°C (no freezing)
Storage ambient humidity
35 to 80% RH (no condensation)
Atmosphere
No corrosive gas, explosive gas, or dust
Degree of protection
IP4X
Weight
Approx. 140 g (except for the cable)
Function list
Menu
Description
Main
Sub 1
Sub 2
Sub 3
Sub 4
Operation
&
setting
Operation
Jog
Set the speed and perform the jog movement.
Inching
Set the speed and distance and perform the inching movement.
Point
Select the point number and perform the point movement.
Origin return
Perform the origin return.
Servo
Turn the servo ON/OFF.
Point
Data
settings
Position
setting
(teaching)
MDI
Set the point data (position) via key input.
Jog
Set the point data (position) via jog movement.
Inching
Set the point data (position) via inching movement.
Direct
Set the point data (position) using the position of the actual machinery.
Non-positional settings Set the point data (positioning width, mode, speed, acceleration, deceleration, pressing current, pressing speed, pressing distance).
Data initialization
Return the point data to the factory defaults.
Parameter
Data settings
Set the parameter data.
Data initialization
Return the parameter data to the factory defaults.
PIO test
Forcefully turn the I/O connector input signal display and the output signal ON/OFF.
Current position output test *
Forcefully output the current position output signal.
Monitor
Actuator (position, speed)
Display the current position and speed.
PIO
Display the I/O connector's input and output signals.
Number of pulses *
Display the count for the number of input pulsetrains.
Alarm
Display the current and past ten alarms.
Version
Display the versions of the handy terminal and the controller.
External dimensions and the names and functions of each part
2
ETP2
Model No. Cable length
How to order
Teaching is simple
Dedicated power supply not required
Can be used with conventional models
It can be used in the same
manner for the EC controllers.
Features
STOP
UP
DOWN
LEFT
RIGHT
106
2000
173
68
72
36.5
23
22.5
1
2
3
4
5
39